Ambient conditions
Temperature
tested to DIN EN 60068-2-2:1994, DIN IEC 68-2-1,
DIN IEC 68-2-14
- operation
+ 5 C to +45 C
40 C for CD-ROM operation
- storage/transport
- 20 C to +60 C
- gradient
max 10 C/h (no condensation)
rel. humidity
tested to DIN IEC 68-2-3, DIN IEC 68-2-30,
DIN IEC 68-2-56
- operation
5% to 80% at 25 C (no condensation)
- storage/transport
5% to 95% at 25 C (no condensation)
Mechanical specifications
Vibration
tested to DIN IEC 68-2-6
- operation
10 to 58 Hz: 0.0375 mm, 58 to 500 Hz: 4.9 m/s
- transport
5 to 9 Hz: 3,5 mm, 9 to 500 Hz: 9.8 m/s
Shock
tested to DIN IEC 68-2-29
- operation
50 m/s
- storage
250 m/s
Motherboard
Processor
see Logbook
Internal processor cache
2 x 8 KB
Main memory
see Logbook
max. 128 MB
Second level cache
see Logbook
Expansion slots
RI25/RI45: 6 ISA long format/2 PCI long format
If the device has a SafeCard, this occupies one ISA expansion
slot.
max. admissable power
5V 2A; 12V 0.3 A; -12 V 0.05 A; -5 V 0.05 A
consumption per ISA slot
(the sum of 5V 9A must not be exceeded)
max. admissable power
5V 2A; 12V 0.5A; -12V 0.1A; -5V 0.1A
consumption per PCI slot
Drives
Floppy disk drive
3.5" (1.44 MB)
Hard disk drive
3.5" EIDE type see Logbook
CD-ROM drive
650 MBytes, type see Logbook
CD-ROM port
EIDE (secondary)
1-8
2
, 30 ms, 100 shocks
2
, 6 ms, 1000 shocks
SIMATIC PC RI25/45