3.4
Measuring Systems and Resolutions
The PMIX resolution is depending on the selected basis measuring system (see type designation 8).
The following table will show all available versions.
Table 1: Measuring Systems and Resolutions
Measuring System
LMIX
EMIX
EMIX23
IZ14E/15E/16E/17E
3.5
Power Supply Voltages and Output Levels
For the LMIX and EMIX based versions, the following combinations are available:
1.
Order suffix 00* = 10 ... 30 VDC power supply / output levels 10 ... 30 V-HTL
2.
Order suffix 01* = 10 ... 30 VDC power supply / output levels 5 V-TTL line driver
3.
Order suffix 11* =
* Order suffix (see type designation 8)
Note: To reach the largest possible interference distance it is recommended to supply the
PMIX linear encoder with 10 ... 30 VDC and to select the A/B signals 5 V-TTL-compatible
with differential evaluation.
3.6
Pulse diagram
A
A'
B
B'
Z
Z'
Figure 2: Output pulse diagram
Resolution
0.1 mm at single edge triggering
0.025 mm at four edge triggering
0.01 mm at four edge triggering
0.001 mm at four edge triggering
0.01 mm / 0.1 mm (einstellbar via Parameter)
5 VDC power supply / output levels 5 V-TTL line driver
Magnetic tape pole pitch
5 mm
2 mm
2 mm
2.5 mm
Channel A and B are
phase shifted by 90°
The index pulse output is
periodically every 2 mm (EMIX)
resp. 5 mm (LMIX)