TROUBLESHOOTING GUIDE (continued)
LED PANEL
CODE
LED Panel Code Flash & Alarm On (NOTE: Always turn off the power before cleaning and servicing).
1. Circulation line is blocked.
2. Incorrect inlet and outlet hose
direction.
3.
Scale on flow sensor pins inside the
titanium electrode.
4.
Titanium electrode cord is loose.
5. Device is set and operating in
backwash, rinse or waste mode.
6.
Titanium electrode failure.
1. Dirt or scale on titanium
plates.
2. Low salt level / No salt.
3.
Titanium electrode cord is loose.
4. Possible electrolytic cell failure.
1. High salt level.
2. Water Temperature > 35ºC.
3. Titanium electrode failure.
1. LED display is off and the "SERVICE"
light is on - the system does not power
up.
2.
Control station failure.
1. The LED display shows a red dot only and
unit does not respond - the electrodes(s)
is/are short circuited.
2. Control station failure.
SAVE THESE INSTRUCTIONS
(345IO) SAND FILTER PUMP COMBO ENGLISH 7.5" X 10.3" PANTONE 295U 07/10/2019
PROBLEM
electrode
SOLUTION
• If your unit has plunger valves, ensure that
they are open.
Clear the basket and cell housing from debris
and dirt.
See "Maintenance" section.
• Depress the 6-way valve, release all trapped
air in the circulation line.
• Check the direction of the inlet and the outlet
hose. Reverse the hoses if necessary. See
"Set Up Instructions".
Clean the titanium electrode.
E.C.O. Electrodes Cleaning" section.
Plug the cord into the titanium electrode and
tighten the plug collar firmly.
• Ignore the alarm, finish the backwash, rinse
or waste operation then turn the power switch
OFF and ON again to reset the alarm.
• Contact Intex Service Center.
Remove the titanium electrode for inspection.
Clean it if necessary.
See "Titanium & E.C.O.
Electrodes Cleaning" section.
• Add salt. See "Salt & Pool Water Volumes".
Plug the cord into the titanium electrode and
tighten the plug collar firmly.
• Contact Intex Service Center. Replace the
cell if needed.
• Partially drain the pool and refill it with fresh
water. See "Salt & Pool Water Volumes".
• Contact Intex Service Center.
• Household voltage is too high or too low (+ 20%).
Check the voltage is within the range stated on the
device housing.
• Contact Intex Service Center.
• Remove and clean the electrode(s). Replace the
electrode(s) if needed.
• Contact Intex Service Center.
English
345A
See "Titanium &
Page 33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eco20230-2Eco15220-2Eco20220-2

Table of Contents