Intex ECO15230-2 Owner's Manual page 12

220-230 v, 50 hz, 300 w/520 w, hmax 5 m hmin 0.19 m ipx4 max. water temperature 35 degrees c
Table of Contents

Advertisement

SETUP INSTRUCTIONS (continued)
Cell housing installation:
1.
Align
the notch on the electrodes to the connection ridges in the cell housing electrode
holes. Insert the electrodes into the respective holes
2.
Attached
the cell housing (46) to the tank base
3.
Plug
in the electrodes' line cords to the respective electrodes (48 & 49), tighten the plugs
collars and electrodes cell housing collars by hand
4.
Place
an L-shape o-ring (11) on the cell housing inlet and 6-way valve outlet connection.
In a clockwise motion connect the sand filter interconnecting hose (13) between the cell
housing inlet and the 6-way valve outlet connection
5.
Place an L-shape o-ring (11) on
In a clockwise motion connect the
pump motor outlet and the 6-way valve inlet connection (see drawing 27).
SAVE THESE INSTRUCTIONS
(345IO) SAND FILTER PUMP COMBO ENGLISH 7.5" X 10.3" PANTONE 295U 07/10/2019
(see drawing 22).
(see drawings 23 & 24).
(see drawing 25).
(see drawing 26).
the
pump motor outlet and the 6-way valve inlet connection.
other
sand filter interconnecting hose (13) between the
22
24
26
13
13
English
345A
23
25
27
Page 12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eco20230-2Eco15220-2Eco20220-2

Table of Contents