SETUP INSTRUCTIONS (continued)
Cell housing installation:
1.
Align
the notch on the electrodes to the connection ridges in the cell housing electrode
holes. Insert the electrodes into the respective holes
2.
Attached
the cell housing (46) to the tank base
3.
Plug
in the electrodes' line cords to the respective electrodes (48 & 49), tighten the plugs
collars and electrodes cell housing collars by hand
4.
Place
an L-shape o-ring (11) on the cell housing inlet and 6-way valve outlet connection.
In a clockwise motion connect the sand filter interconnecting hose (13) between the cell
housing inlet and the 6-way valve outlet connection
5.
Place an L-shape o-ring (11) on
In a clockwise motion connect the
pump motor outlet and the 6-way valve inlet connection (see drawing 27).