Rs485-Termination Jumpers; Parallel Port Lpt1 - Lippert Cool SpaceRunner-LX800 Technical Manual

Pc/104-plus cpu board
Table of Contents

Advertisement

RS485-Termination Jumpers

Connector type IDC4 pin header 2.00 mm
Use 2 mm jumpers to terminate lines correctly.
There are two jumpers COM1 and COM2, respectively.
The RS485 termination jumpers are located at the top of the printed circuit board, see chapter
Pin
Signal
1
TX+
3
RX+
When the jumper is set, the differential pairs
are terminated with 120Ω between them.
(e.g. RX+ and RX-)
Additionally, positive/negative receive lines are pulled up/down
with 1kΩ to 5V/GND in order to protect the transceivers of the
Cool SpaceRunner-LX800 from overvoltage.
It is recommended to protect the ports of the external device in
the same way!

3.11 Parallel Port LPT1

The parallel port is located on an IDC26 header. An adapter cable with a standard DSUB-25 female
connector is available.
The parallel port is programmable in BIOS.
Entering Motherboard Device Configuration
configuration of LPT1 is accessible.
LPT1 Parameter
Base Address
Mode
TME-104P-CSR-LX800-R1V5.doc
Pin
Signal
2
TX-
4
RX-
Caution: Termination Resistors should not be used in RS232 Mode!
Otherwise, the serial ports will not work.
Disabled, 0x378
0x3BC and 0x278 are not recommended, because of a possible
conflict with the PCI to ISA Bridge
Compatible, PS/2 Bi-directional, EPP 1.7, EPP 1.9
IRQ
Disabled, IRQ 5, IRQ 7, IRQ 9, IRQ 10, IRQ 11
DMA
None, Channel 1, Channel 3
Serial and Parallel Device Configurations,
Possible Settings
Rev 1.5
2 .2
1 5 0 H
23 (44)

Advertisement

Table of Contents