If
• a foreign body, which cannot be shredded and
pumped away by the Sololift, has inadvertently
been flushed through the toilet or
• the water level in the toilet rises more than nor-
mally when flushing the toilet,
clean the strainer according to the following pro-
cedure:
1. Pull the plug out of the wall socket.
2. Remove the protective caps covering the four
screws securing the cover on the Sololift.
3. Remove the four screws and the cover.
4. Take out the strainer and remove the foreign
body.
5. Clean the strainer.
6. Replace the strainer, put the cover back on and
replace the four screws and caps.