Grundfos Sololift2 CWC-3 Installation And Operating Instructions Manual

Grundfos Sololift2 CWC-3 Installation And Operating Instructions Manual

Small, compact automatic lifting station suitable for pumping domestic wastewater and sewage off places in private dwellings where wastewater cannot be led directly to the sewer by means of a natural downward slope

Advertisement

Sololift2 CWC-3
Installation and operating instructions
Other languages
Sololift2 CWC-3
http://net.grundfos.com/qr/i/97771616
GRUNDFOS INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Grundfos Sololift2 CWC-3

  • Page 1 GRUNDFOS INSTRUCTIONS Sololift2 CWC-3 Installation and operating instructions Other languages Sololift2 CWC-3 http://net.grundfos.com/qr/i/97771616...
  • Page 2: Table Of Contents

    English (GB) Installation and operating instructions Original installation and operating instructions 2. General description The CWC-3 is a small, compact automatic lifting CONTENTS station suitable for pumping domestic wastewater and sewage off places in private dwellings where Page wastewater cannot be led directly to the sewer by Symbols used in this document means of a natural downward slope.
  • Page 3: Pumped Liquids

    4. Pumped liquids 6. Electrical connection Domestic wastewater and sewage containing toilet Make sure that the product is suitable for the supply paper and faeces. voltage and frequency available at the installation site. Ordinary liquids for cleaning of the appliances connected.
  • Page 4: Service

    Turn the shaft right and left to free the impeller/ If you have any questions, please contact the grinder from dirt. nearest Grundfos company or service workshop. 1.4 Fit the plug, and switch on the power supply to check if the impeller/grinder can rotate freely.
  • Page 5: Technical Data

    Pressure switch pipe blocked 8. Technical data The pressure switch unit can be removed Supply voltage Note separately. 1 x 220-240 V - 10 %/+ 6 %, 50 Hz. 3.1 If the water level in the tank is above the motor Power consumption flange, disconnect the power supply and drain Max.
  • Page 6: Fault Finding

    9. Fault finding Warning Remove the fuse, pull out the plug, or switch off the power supply. Make sure that the power supply cannot be accidentally switched on. All rotating parts must have stopped moving. The product must only be serviced by trained service staff.
  • Page 7: Disposal

    This product or parts of it must be disposed of in an environmentally sound way: 1. Use the public or private waste collection service. 2. If this is not possible, contact the nearest Grundfos company or service workshop. Subject to alterations.
  • Page 8 Appendix...
  • Page 12 Argentina China Hong Kong Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps (Shanghai) Co. Ltd. GRUNDFOS Pumps (Hong Kong) Ltd. Ruta Panamericana km. 37.500 Centro 10F The Hub, No. 33 Suhong Road Unit 1, Ground floor Industrial Garin Minhang District Siu Wai Industrial Centre 1619 Garín Pcia.
  • Page 13 Malaysia Serbia Turkey GRUNDFOS Pumps Sdn. Bhd. Grundfos Srbija d.o.o. GRUNDFOS POMPA San. ve Tic. Ltd. 7 Jalan Peguam U1/25 Omladinskih brigada 90b Sti. Glenmarie Industrial Park 11070 Novi Beograd Gebze Organize Sanayi Bölgesi 40150 Shah Alam Phone: +381 11 2258 740...
  • Page 14 97771616 0716 ECM: 1188679 www.grundfos.com...