PIN
1
2
3
4
5
6
7
8
9
10
I/O Terminal on router Serial port (RS485 or RS232)
Port 3 (GND)
Port 4 (RX)
Port 5 (TX)
If not through, can switch Port4 and Port5.
2.6 Grounding
To ensure a safe, stable and reliable H700 series operation, Router cabinet should be
grounded properly.
Signal
Description
+5-40V
VCC
+5~60V option
GND
Ground
GND
Serial Ground
RX
Receive Data
TX
Transmit Data
RST
Reset
DIO0
General Purpose I/O
DIO1
General Purpose I/O
DIO2
General Purpose I/O
DIO3
General Purpose I/O
Pin 5
Pin 2
Pin 3
E-Lins Technology Co.,Limited
Tel: +86-755-29230581 E-mail: sales@e-lins.com
Note
DC
Input,
Current: 12V/1A
Reset Pin has the same
function with reset
button. In the usage, it
needs to be short
connected to the GND.
After giving the device a
1 sec low level, it will
reboot.3 seconds, the
device will restore
factory settings
www.e-lins.com
H700 User Manual