Telnet Configuration; Connecting To The Uds; Uds To Pc Configuration - Bosch Readykey X UDS-10 Setup Manual

Serial tunnel on cnc
Table of Contents

Advertisement

3.2 Telnet Configuration

3.2.1 Connecting to the UDS

The UDSs can be connected outside of the DeviceInstaller by using Windows Telnet. To do this, connect
using the unit's assigned IP Address and a port number of 9999. For example: use the command TELNET
192.168.101.52 9999 at the command prompt.
Notes
1. In the following example, text enclosed in a gray box represents the screen display of whatever
application is hosting the Telnet session.
2. Bold text in the gray box represent example values.
3. This is an example configuration with no gateway. If a gateway is required on a specific network, it
should be configured on the relevant gateway.
When Telnet has connected to the UDS, the following (or similar) is displayed:
*** Lantronix Universal Device Server ***
Serial Number 5423446
Software Version V04.2 (000908)
Press Enter to go into Setup Mode
Press Enter.
Hardware: Ethernet Autodetect
IP addr 192.168.31.202, no gateway set,netmask 255.255.255.000
***************** Security *****************
Telnet setup is
TFTP download is
Port 77FEh is
Web Server is
Enhanced password is disabled
***************** Channel 1 *****************
Baudrate 9600, I/F Mode 4C, Flow 00
Port 10001
Datagram Type 01
Pack Cntrl:
00
Remote IP Adr: 192.168.004.243, Port 00000
Change Setup
: 0 Server configuration
1 Channel 1 configuration
6 Security
7 Factory defaults
8 Exit without save
9 Save and exit

3.2.2 UDS to PC Configuration

This section describes the configuration of the UDS for network operation.
Configuration
From the main menu (displayed above) type 0 (for the option Server Configuration) and press Enter.
IP Address : (000) 192.(000) 168.(000) 101.(000) 27<enter>
Set Gateway IP Address (Y) Y<enter>
Gateway IP addr (000) 192.(000) 168.(000) 101.(000) 254<enter>
Netmask: Number of Bits for Host Part (0=default) (00) 8<enter>
Change telnet config password (N) N<enter>
17553v1.0
MAC address 00:20:4A:54:5B:96
enabled
enabled
enabled
enabled
Your choice ?
7