Bosch Readykey X UDS-10 Setup Manual page 8

Serial tunnel on cnc
Table of Contents

Advertisement

Enter the following information:
IP Address
Set Gateway Address
Gateway IP Addr
Netmask
Change telnet config
password
*** basic parameters
Hardware: Ethernet Autodetect
IP addr 192.168.004.241, no gateway set,netmask 255.255.255.000
***************** Channel 1 *****************
Baudrate 9600, I/F Mode 4C, Flow 00
Port 10001
Datagram Type 01
Pack Cntrl:
00
Remote IP Adr: 192.168.004.147, Port 00000
Change Setup
: 0 Server configuration
1 Channel 1 configuration
7 Factory defaults
8 Exit without save
9 Save and exit
8
The IP Address displayed will be the one that was entered in
Section 3.1. Do not change this value; press Enter to move onto
the next step.
Press the Y key, and press Enter.
Enter the gateway IP address and press Enter.
The subnet mask ('netmask') is entered in an unusual fashion. The
prompt asks for the number of bits. For example, 255.255.255.0
corresponds to 8 bits. See the table below for other examples.
Mask
255.0.0.0
255.255.0.0
255.255.240.0
255.255.248.0
255.255.254.0
255.255.255.0
255.255.255.128
255.255.255.192
255.255.255.224
255.255.255.240
255.255.255.248
Press the N key and press Enter.
The basic parameters menu will be displayed:
Bits
24
16
12
11
9
8
7
6
5
4
3
Your choice ?