Structure and function of the videographic recorder

Fig. 4:
Structure of the
recorder window
Page 6
4
Structure and function of the videographic recorder
pH
POOL
1
8,00
6,40
4,80
3,20
1,60
0,00
15:30
18:30
21:30
24:30
100%
0%
-100%
26 6,70
13 % 08-JUL-2004 17:48
HELP
ZOOM-
ZOOM+
The recorder window is made up of:
• Designation of the parameter
• Pool number and pool name
• Chart for the parameter
• Chart for the control variable of the parameter
• Information line for the selected measured value
• Bar with function keys
Designation of the parameter
Select the parameter using the UP and DOWN arrow keys.
Pool number and pool name
Select the pool using the LEFT and RIGHT arrow keys.
Chart for the parameter
The chart for the parameter shows the y-axis with the units on the far left. Between the chart for
the parameter and the chart for the control variable is the time axis (x-axis). It always displays 24
hours. Times are only displayed where there are also measured values. Otherwise it shows
"00:00".
The red lines indicate the set limits (in the Set Parameter menu: Parameter Alarm)
If the measured values infringe the limit, the trace appears red there.
The blue line is a cursor that you can use to move onto individual measured values to read their
exact value (see below "Information line for the selected measured value" and "Bar with function
keys"). The cursor is positioned exactly on the y-axis to begin with.
Chart for the control variable of the parameter
The diagram for the control variable of the parameter shows the y-axis with the units (%) on the
far left. Between the chart for the parameter and the chart for the control variable is the time axis
(x-axis). It always displays 24 hours.