Maintenance Of The F*-Jb - Pepperl+Fuchs F-JB Series Manual

Fieldbus junction boxes/segment protectors
Table of Contents

Advertisement

F2-JB-#.I, F*-JB-#.*
Maintenance of Cable Glands
10.1
Maintenance of the F*-JB**-...CG Cable Gland
Connectorizing Cables Using F*...CG Cable Glands
1. Strip the insulation of the cable up to about 160 mm.
2. Loosen the cap nut and the seals from the device. Depending on the application, slip Seal 1
& Seal 2 or only the obligatory Seal 2 over the cable as shown:
1. Seal 1, used in the following instance: Type: M20 x 1.5, Terminal area: 5 ... 8 mm
2. Seal 2, obligatory
3. Move the required seal(s) over the cable until after the last seal about 5 mm insulation
protrude before the stripped wire begins:
4. Insert the cable with the seals into the cable gland of the device and tighten the cap nut.
The tightening torques of cap nuts vary depending on the cable type used and must be
determined by the user. As a rule of thumb, the tightening torque is approx. 2.5 Nm for the
F*-JB**-... .CG. See chapter 7.1.
28