Toshiba Carrier MMD-AP0074BH2UL-1 Installation Manual page 21

Multi type air conditioner
Hide thumbs Also See for Carrier MMD-AP0074BH2UL-1:
Table of Contents

Advertisement

Available languages

Available languages

Check code
Outdoor 7-segment display
Wired remote
control display
Auxiliary code
Fan-
A3-IPDU
A3-IPDU
Sub-
IPDU Sub-
code
code
1
2
3
1
2
1
2
01
0D
02
0E
  
03
0F
 
   
04
11
05
12
E31
E31
06
 
13
 
07
  
18
08
19
09
1A
0A
1B
 
0B
 
Circle (): IPDU trouble
0C
 
F01
F02
F03
F04
F04
F05
F05
F06 TE1 sensor
F06
TE2 sensor
F07
F07
F08
F08
01: TG1
F09
F09
02: TG2
F10
F11
— TF sensor
01: TS1 sensor
F12
F12
03: TS3 sensor
01: Comp. 1 side
F13
F13
02: Comp. 2 side
03: Comp. 3 side
F15
F15
F16
F16
F22
F22
F23
F23
F24
F24
F29
F31
F31
01: Comp. 1 side
H01
H01
02: Comp. 2 side
03: Comp. 3 side
01: Comp. 1 side
H02
H02
02: Comp. 2 side
03: Comp. 3 side
01: Comp. 1 side
H03
H03
02: Comp. 2 side
03: Comp. 3 side
H05
H05
H06
H06
H07
H07
39-EN
Wireless remote control
Sensor block display of
Check code name
receiving unit
Operation Timer Ready Flash
Fan-
IPDU
3
1
2
 
IPDU communication trouble
 
 
 
 
ALT Indoor TCJ sensor trouble
ALT Indoor TC2 sensor trouble
ALT Indoor TC1 sensor trouble
ALT TD1 sensor trouble
ALT TD2 sensor trouble
ALT TE1 sensor trouble
TE2 sensor trouble
ALT TL sensor trouble
ALT TO sensor trouble
TG1 sensor trouble
TG2 sensor trouble
ALT Indoor TA sensor trouble
ALT TF sensor trouble
ALT TS1 sensor trouble, TS3 sensor trouble
ALT TH sensor trouble
ALT Outdoor temp. sensor miswiring (TE1, TL)
ALT Outdoor pressure sensor miswiring (Pd, Ps)
ALT TD3 trouble
ALT Ps sensor trouble
ALT Pd sensor trouble
SIM Indoor other trouble
SIM Indoor EEPROM trouble
Compressor break down
Compressor trouble (lock)
Current detect circuit system trouble
TD1 miswiring
Low pressure protective operation
Oil level down detective protection
Check code
Judging
Outdoor 7-segment display
Wired remote
device
control display
Auxiliary code
01: TK1 sensor trouble
02: TK2 sensor trouble
H08
H08
03: TK3 sensor trouble
04: TK4 sensor trouble
05: TK5 sensor trouble
H15
H15
01: TK1 oil circuit system trouble
02: TK2 oil circuit system trouble
H16
H16
03: TK3 oil circuit system trouble
04: TK4 oil circuit system trouble
05: TK5 oil circuit system trouble
H25
H25
L03
L04
L04
I/F
L05
L06
L06 No. of indoor units with priority
L07
L08
L08
L09
L10
L10
L17
L17
L20
L28
L28
Indoor
L29
L29 The same as E31
Indoor
L30
L30 Detected indoor address
Indoor
L31
I/F
P01
I/F
P03
P03
01: Comp. 1 side
I/F
P04
P04
02: Comp. 2 side
03: Comp. 3 side
I/F
00: Detected phase loss
I/F
P05
P05
01: Comp. 1 side
I/F
02: Comp. 2 side
03: Comp. 3 side
Indoor
01: Comp. 1 side
Indoor
P07
P07
02: Comp. 2 side
03: Comp. 3 side
I/F
P10
P10 Detected indoor address
P12
IPDU
P13
P13
I/F
01: TS condition
P15
P15
02: TD condition
I/F
P17
P17
I/F
P18
P18
I/F
P19
P19 Detected outdoor unit number
I/F
P20
P20
Indoor
0
: IGBT circuit
I/F
1
: Location detection circuit trouble
3
: Motor lock-up trouble
IPDU
4
: Motor current was detected.
C
: Abnormal temperature was detected by the TH
sensor.
P22
P22
D
: TH sensor trouble
IPDU
E
: Inverter DC voltage trouble (outdoor unit fan)
Caution)
Although letters 0 to F appear at locations indicated
IPDU
by " ", please ignore them.
01: Comp. 1 side
I/F
P26
P26
02: Comp. 2 side
03: Comp. 3 side
I/F
I/F
– 20 –
Wireless remote control
Sensor block display of
Check code name
receiving unit
Operation Timer Ready Flash
Oil level detective temp sensor trouble
TD2 miswiring
Oil level detective circuit trouble
TD3 miswiring
SIM Indoor center unit duplicated
SIM Outdoor line address duplicated
Duplicated indoor units with priority
SIM
(Displayed in indoor unit with priority)
Duplicated indoor units with priority
SIM
(Displayed in unit other than indoor unit
with priority)
SIM Group line in individual indoor unit
SIM Indoor group / Address unset
SIM Indoor capacity unset
SIM Outdoor capacity unset
SIM Outdoor unit model unmatch trouble
SIM Duplicated central control addresses
SIM Over No. of connected outdoor units
SIM No. of IPDU trouble
SIM Indoor outside interlock
Extended I/C trouble
ALT Indoor fan motor trouble
ALT Discharge temp. TD1 trouble
ALT High-pressure SW system operation
Phase loss trouble / interruption of
power supply
ALT
Inverter DC voltage (Vdc) trouble
ALT Heat sink overheat trouble
ALT Indoor overflow trouble
ALT Indoor fan motor trouble or duct setting miss
ALT Outdoor liquid back detection trouble
ALT Gas leak detection
ALT Discharge temp. TD2 trouble
ALT Discharge temp. TD3 trouble
ALT 4-way valve inverse trouble
ALT High-pressure protective operation
ALT Outdoor fan IPDU trouble
ALT G-TR short protection trouble
Judging
device
I/F
I/F
I/F
I/F
Indoor
I/F
I/F
I/F
Indoor
Indoor, I/F
Indoor
I/F
I/F
Indoor
I/F
I/F
Indoor
I/F
Indoor
I/F
IPDU
I/F
IPDU, I/F
Indoor
Indoor
I/F
I/F
I/F
I/F
I/F
I/F
IPDU
EN
IPDU
40-EN