Air Inlet
D
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to the ground
or to a wall-mounted bracket.
Outdoor Unit Dimensions (inches)
Width (W) x Height (H) x Depth (D)
31.5 x 21.8 x 13.1 (inches)
DIY-12-HP-C-115B
800 x 554 x 333 mm
33.25 x 27.63 x 14.29 (inches)
DIY-18-HP-C-230B
845 x 702 x 363 mm
37.21 x 31.9 x 16.53 (inches)
DIY-24-HP-C-230B
946 x 810 x 420 mm
37.21 x 31.9 x 16.53 (inches)
DIY-36-HP-C-230B
946 x 810 x 420 mm
If you will install the unit on the ground or on a
concrete mounting platform, do the following:
1.
Mark the positions for four expansion bolts based
on dimensions in the Unit Mounting Dimensions
chart.
2.
Pre-drill holes for expansion bolts.
3.
Clean concrete dust away from holes.
4.
Place a nut on the end of each expansion bolt.
5.
Hammer expansion bolts into the pre-drilled
holes.
Page 25
Outdoor Unit Installation
Air Inlet
Air Outlet
mrcool.com
B
Fig. 5.5
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor unit
sizes and the distance between their
mounting feet. Prepare the installation base
of the unit according to the dimensions below.
Mounting Dimensions (inches)
Width (A)
20.24 in.
514 mm
21.26 in.
540 mm
26.5 in.
673 mm
26.5 in.
673 mm
6.
Remove the nuts from expansion bolts, and
place outdoor unit on bolts.
7.
Put washer on each expansion bolt, then
replace the nuts.
8.
Using a wrench, tighten each nut until snug.
WHEN DRILLING INTO CONCRETE,
EYE PROTECTION IS RECOMMENDED
AT ALL TIMES.