ENGLISH - 6 MICROSCANNER will not function properly with a 9 Volt Carbon Battery.
Page 7
(1-800-638-3497) (U.S. and Canada only) (.AX) (U.S. and Canada only) ENGLISH - 7...
Page 8
ENGLISH - 8 MICROSCANNER Tests 1. Connect the cable to be tested to the jack (identified on the unit right above the modular 8 jack). 2. To display the Wiremap screen, press the key until the word appears on the screen.
Page 9
If a cable is wired correctly, pin-to-pin, but there is a split pair, Wiremap will display . .or example a wire from the 1 - 2 pair could be twisted with a wire from the 3 - 6 pair. ENGLISH - 9...
Page 10
ENGLISH - 10 1. Simply plug the two ends of a cable into the two modular 8 jacks ( ) on MICROSCANNER. 2. To display the Wiremap screen, press the key until the word appears on the screen.
Page 11
1. Connect the cable to be tested to the jack (identified on the unit right above the modular 8 jack). 2. To display the length screen, press the key until the word appears on the screen. The overall cable length will be shown.
Page 12
(identified on the unit right above the modular 8 jack). 2. To display the length screen, press the key until the word appears on the screen. MICROSCANNER displays the word followed by the length to the hub. 3. When MICROSCANNER displays...
Page 13
(identified on the unit right above the modular 8 jack). 2. To display the length screen, press the key until the word appears on the screen. MICROSCANNER displays the word followed by the length to the ENGLISH - 13...
Page 14
ENGLISH - 14 3. When MICROSCANNER displays the cable length, press the key to activate the blinking Hub light. 1. Press the key to display Pair 1 - 2 length. 2. Press the key again to display the other pair combinations.
Page 15
(MICROSCANNER PRO) This feature is available in the residential version or when using the COAX upgrade kit. Ω 1. Attach the supplied COAX adapter to the jack (identified on the unit right above the modular 8 jack). 2. Connect the cable to be tested to the jack.
Page 16
ENGLISH - 16 1. Connect the cable to be tested to the jack (identified on the unit right above the modular 8 jack). 2. To display the Office Identifier screen, press key until the word displayed on the screen. 3. Insert the Office Identifier plugs into wall outlets in the offices you wish to locate.
Page 17
(MICROSCANNER PRO) 1. Attach the coax adapter to the jack (identified on the unit right above the modular 8 jack). 2. To display the Office Identifier screen, press key until the word displayed on the screen. 3. Insert the Office Identifier plugs into wall outlets in the offices you wish to locate.
Page 18
ENGLISH - 18 1. To display the Toner screen, press the key until the words are displayed on the screen. 2. To select a different tone sequence press the key.