SECTION 3: INSTALLATION

Power Supply Installation

Purpose
Power Supply Enclosure is part of the complete
Bioshield UV Systems™ Series.
Frequency
Required
with
new
replacement of outdated equipment.
Parts and Required Equipment
• Set of Slot and Phillips Head Screwdrivers
• Adjustable Wrench
• Pliers
• Wall Struts or Braces
• Supplied Enclosure Mounting Hardware
• Personal Safety Equipment
General risk due to suspended load.
General risk due to electricity.
General risk due to pressurized piping or UV
Vessel.
Procedure
1. Use the supplied enclosure mounting feet if the
Power Supply Enclosure is going to be mounted
on a wall.
2. Mount the Power Supply Enclosure close to the
UV Vessel so that the lamp cables reach between
the Power Supply Enclosure and the UV Vessel.
The power supply lamp and sensor cables are
approximately 20' long to provide an adequate
routing length from the power supply enclosure to
the UV vessel.
3. The Power Supply Enclosure should be mounted so
that the PLC is visible to the operator. The location
used for mounting the Power Supply Enclosure
should be as dry and cool as possible.
BIOSHIELD
Commercial UV Sterilizer Installation and User's Guide
®
construction,
retro-fit
4. The Power Supply Enclosure should be located in
a place that provides sufficient weather protection,
in the case of outdoor installation. Sufficient space
near the cooling fan's intake and exhaust must be
provided.
5. The Power Supply Enclosure must be supplied
with the correct operating voltage (120/230 VAC).
Failure to supply the UV System with the correct
or
operating voltage can damage the ballasts and
other electrical hardware. Use only a well- ground
electrical circuit.
6. The UV System is equipped with an equipment-
grounding conductor and a grounding plug. The
grounding plug must be installed and grounded in
accordance with all local codes and ordinances.
Improper connection of the equipment- grounding
conductor can result in electrocution. Check
with a qualified electrician or service personnel if
you question whether the equipment is properly
grounded.
7. Input power to the Power Supply Enclosure is
switched on and off using the enclosure's External
On/Off switch or Remote On/Off control.
NOTE: All UV control enclosures that utilize our PLC
should be mounted with considerations to
other devices that emit, or are suspected of
emitting, any EMI & RFI noise and that any
sensors used in conjunction with our PLC
should use industry standard procedures to
avoid EMI & RFI noise issues.