Testing
Caution! The alarm is very loud! Only the first alarm sequence is quieter.
1. Press and hold the button.
2. The LED indicator will glow white and you will hear a short beep - keep holding.
3. Release the button when you hear the first alarm sequence.
4. Move away from the device to protect your hearing.
Battery replacement (page 5)
1. Remove the device from the cover by turning it counter-clockwise.
2. Pull the paper strip to take out the battery.
3. Press and hold the button for at least one second.
4. Insert a new CR123A battery observing the polarities shown inside.
5. Attach the device to its cover by turning it clockwise and perform the test.
Use only type of battery specified in this manual and keep proper polarity!
Z-Wave procedures
Adding to the network
1. Place the device within direct range of the Z-Wave controller.
2. Set the main Z-Wave controller into adding mode.
3. Quickly, triple click the button located on the casing.
4. Wait for the device to be added into the system.
5. Install the device in desired location.
Reset
1. Press and hold the button.
2. Release the button when LED indicator glows white.
3. Click the button when LED indicator glows yellow.
4. After few seconds the device will be reset (confirmed by red LED indicator).
12