Maintenance - Edition 11.2011
– Connect compressed air supply -2- to extraction unit -VAS
6277/1- .
– Extract fluid by carefully pulling metering lever -3-.
WARNING
♦ Turn ventilation -1- in direction of the well ventilated room,
do not inhale emitting vapours.
♦ Ensure the extraction container of the extraction unit -VAS
6277/1- is not overfilled during extraction process. A dan‐
ger of overflowing exists.
♦ Finish extraction process when the container is approx.
2/3 full, see -arrow 5-.
♦ If necessary repeat extraction process.
♦ Do not reuse extracted (used) additive fluid.
♦ Dispose of extracted (used) additive fluid according to op‐
erating instructions ⇒ ServiceNet; HSO; Environmental
Handbook 3 .
– If the total quantity of fluid has been extracted, separate com‐
pressed air supply.
Replenishing fluid:
– Bolt container with new additive fluid -1- to filling device -VAS
6277/2- .
– Connect filling device -VAS 6277/2- and overflow protection -
VAS 6277/3- with connections -3- and -4- to respective con‐
nections
⇒ page 34
– Additionally secure hose clamp e.g. hose clamp -VAS 6277/2-
on hose end of filling device -3094-
Note
The hose clamp prevents that after filling and when pulling off
hose, fluid is drained from filling hose.
The additive container has a capacity of approx. 4.5 to 5 litres.
– Open valve -2- and drain fluid into additive container.
Note
The system must not be overfilled.
In case of overfilling fluid is visible on hose of overflow pro‐
tection -VAS 6277/3- .