1.
Switch on the main power supply, the 'POWER' LED would light up.
2.
Turn on the water supply at the stop valve.
3.
Turn on the Temperature Control Knob. The 'HEATER' LED would light up and the
water temperature will be increased accordingly as the knob being turned
clockwise from 'ON' to 'MAX'.
4.
For normal cold shower, just turn the Temperature Control Knob to 'OFF' position.
5.
Switch off the power supply when not in use.

5. GENERAL MAINTENANCE

DO NOT USE THINNER, ALCOHOL OR PETROL
You may clean the heater with a damp cloth and mild detergent but do not use thinner,
alcohol, petrol or any other organic solution.
CLEAN FILTER REGULARLY (Diagram 6)
a)
Remove the filter mesh at the stop valve (for filter type only) by turning the knob filter
counter clockwise direction and pull out the knob (Diagram 6). Flush it with water to
remove any trapped sediments. Install the knob filter back to its original position.
stop valve
Diagram 6
9