Commands
Code
Command explanation
15
Characteristic curve shift
The characteristic curve of the scale, determined
by the scale adjustment, is shifted temporarily so
that the current scale load corresponds with the
zero point (zero weight).
Scale commands
21
Scale zero setting
The current weight is set to zero. The tare weight is
deleted at the same time.
22
Tare
The current weight is set to zero and the weight
display is simultaneously designated as "Net".
23
Delete tare
The tare weight is deleted. The current weight is
displayed and the designation is changed from
"Net" to "Gross", the "Net" designation and, if
necessary, the "Preset tare" status is reset.
24
Accept tare entry from DS 15
The defined tare weight is accepted as tare and the
weight display is simultaneously designated as
"Net" and the "Preset tare pT" status is set.
25
Switch on increased resolution
Activate output / display of weight value with
increased resolution for 5 seconds.
26
Transfer tare weight from S7 control range
Tare specification from S7 control range valid. The
weight display is simultaneously designated as
"Net" and the status "Preset tare pT" is set.
Table 6-1
SIWAREX MS command list
More information on command transfers from the control program via the SIMATIC interface can
be found in chapter
8 Programming in STEP 7.
6-36
SIWAREX MS
Comment
Executable if no
write protection
(jumper P-PR)

Advertisement