Weighing Functions
5.7.1
DS 30 – Scale Status
The status information provides details of the current state of the scale.
Bit No.
Name
0
Limit value 1
1
Limit value 2
2
Scale tared
3
Preset tare
4
Max+9e
5
¼d zero
6
Standstill
7
Module adjusted
8
Parameter definition
blocked
9
Min. weighing range
undershot
10
--
11
--
12
--
13
--
14
Booting
15
Module group fault
Table 5-7
Status information
5-32
SIWAREX MS
Range of Values / Meaning
1 = Limit value 1 has responded
1 = Limit value 2 has responded
1 = Tare memory occupied (≠ 0)
1 = Tare memory contains ext. default value
1 = Gross weighing range exceeded or undershot by more than 9 display steps
1 = Gross less than ± 0.25d (d corresponds to set numeral step)
1 = Standstill exists
1 = Module adjusted
1 = Write protect switch active;
(No adjustment parameter DS3 or adjustment commands can be sent)
1 = Min. weighing range undershot
--
--
--
--
The SIWAREX module is starting up
1 = Global module fault / operating error (SF)