10. Open the [Maintenance] screen.
The [TeamViewer] button is displayed.
11. Press the [TeamViewer] button.
TeamViewer launches.

Restoring to factory default values

Main Unit
Performing the following operation will remove all settings, updates, installed device drivers
and applications, such as Skype for Business, and restore the factory default settings.
Required devices
Wired USB keyboard
Note
If you use a wireless keyboard, it may not work correctly when entering the BIOS
password, and an Invalid Password error may occur.
USB mouse
HDMI display or DisplayPort display
1.
Connect a wired USB keyboard, USB mouse, and display to the unit.
2.
Press the power button on the unit to turn it on.
3.
Immediately after powering on, repeatedly press the Delete key on the keyboard until the
BIOS password screen appears.
4.
Enter the password on the BIOS password entry screen, and press Enter on the keyboard.
The BIOS screen appears.
The password to enter is a password set by the user. If the password has not been changed
from the default setting, change the password as described in "Changing the Default
Password" (page 84).
5.
Change "Boot Option #1" in the [Boot] menu to "Acronis Loader."
6.
Select "Save changes and reset" from the [Save & Exit] menu, and press Enter on the
keyboard.
7.
In the "Save configuration and reset?" message dialog, select [Yes], and press Enter on
the keyboard.
The change in startup method in order to return to factory default status is completed.
Note
Do not select "Save changes and exit."
8.
The unit reboots. Repeatedly press the "0" (zero) key above the alphabetic keys on the
keyboard until the password entry screen appears.
The unit boots using the startup method in order to return to factory default status.