Wiring Diagram - Superior Fireplaces VRT4032ZMN Installation And Operation Instructions Manual

Radiant and louvered faced fireplace system with logs and thermostat blower
Table of Contents

Advertisement

WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes
may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM
Fireplace produces unwanted
odors
Fireplace shuts off in use (ODS
operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
126868-01D
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Heater burning vapors from
paint, hair spray, glues, clean-
ers, chemicals, new carpet,
etc. (See IMPORTANT state-
ment above)
2. Low fuel supply (propane/LP
only)
3. Gas leak. See Warning state-
ment above
1. Not enough fresh air is avail-
able
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Warning state-
ment above
2. Control valve or gas control
defective
1. Foreign matter between con-
trol valve and burner
2. Gas leak. See Warning state-
ment above

WIRING DIAGRAM

disconnection when servicing controls.
Wiring errors can cause improper and
dangerous operation. Verify proper opera-
tion after servicing.
Thermopile
SuperiorFireplaces.us.com
REMEDY
1. Open window to ventilate
room. Stop using odor caus-
ing products while heater is
running
2. Refi ll supply tank (propane/
LP only)
3. Locate and correct all leaks
(see Checking Gas Connec-
tions, Page 16)
1. Open window and/or door for
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, Page 25)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, Page 16)
2. Replace control valve or gas
control
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, Page 16)
CAUTION: Label all wires prior to
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrt4032zmpVrt4036zmnLbg24bmVrt4036zmpLbg18bm

Table of Contents