PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 21).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP supply
tank valve.
3. Make sure control knob of fi replace is in the OFF
position.
4. Check all joints from equipment shutoff valve to
gas control valve (see Figures 22 or 23). Apply
noncorrosive leak detection fl uid to all joints.
Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light fi replace (see Operation, Page 22). Check
all other internal joints for leaks.
7. Turn off fi replace (see To Turn Off Gas to Ap-
pliance, Page 23).
Equipment
Shutoff
Valve
Figure 21 - Equipment Shutoff Valve
Gas Control Valve
Figure 22 - Checking Gas Joints for Natural Gas
Equipment Shutoff Valve
Gas Control Valve
Figure 23 - Checking Gas Joints for Propane/
LP Gas
126868-01D
INSTALLATION
Continued
INSTALLING LOGS
the parts in accordance with these
diagrams or failure to use only parts
specifi cally approved with this appli-
ance may result in property damage
or personal injury.
data plates attached to the heater
base assembly. The data plates con-
tain important safety and warranty
information.
Open
periodically thereafter, check to en-
sure that no fl ame comes in contact
with any log. With the heater set to
High, check to see if fl ame contact any
Closed
log. If so, reposition logs according
to the log installation instructions in
this manual. Flames contacting logs
Equipment
will create soot.
Shutoff Valve
1. Place fi ber ramp log in center of chassis as
Gas Meter
Ramp Log
Propane/LP
Supply Tank
SuperiorFireplaces.us.com
WARNING: Failure to position
CAUTION: Do not remove the
WARNING: After installation and
shown in Figure 24. The fi ber ramp log can be
identifi ed by the shape and much lighter weight
when compared to the other logs. The log must
sit fl at on the black sheet metal and behind the
left metal tab as shown. Make sure the side
marked ''BOTTOM'' is setting down.
Metal
Tab
Figure 24 - Installing Fiber Ramp Log