Superior Fireplaces VRT4032ZMN Installation And Operation Instructions Manual page 10

Radiant and louvered faced fireplace system with logs and thermostat blower
Table of Contents

Advertisement

ASSEMBLING AND ATTACHING OPTIONAL
PERIMETER TRIM
IMPORTANT: If you are recessing the fi rebox in a
wall, do not attach trim at this time. See Built-In
Fireplace Installation, Page 12.
NOTE: These instructions show assembling and
attaching trim to fi replace.
1. Remove packaging from three pieces of
trim.
2. Locate four screws, two adjusting plates with
set screws, and two shims in the hardware
packet.
3. Align shim under adjusting plate as shown in
Figure 6.
4. Slide one end of adjusting plate/shim in slot on
mitered edge of top trim (see Figure 6).
5. Slide other end of adjusting plate/shim in slot
on mitered edge of side trim (see Figure 6).
6. While fi rmly holding edges of trim together,
tighten both set screws on the adjusting plate
with slotted screwdriver.
7. Repeat steps 1 through 6 for other side.
8. Tighten trim hanging screws (#10 x 6.25
shoulder) into holes in cabinets. Place the
assembled trim onto fi replace cabinet. Align
hanging notches on trim with hanging screws
on side of fi replace (see Figure 7). Push trim
fi rmly into place, sliding hanging notches over
hanging screws.
Adjusting
Side Trim
Plate
Shim
Mitered
Slot
Edge
Figure 6 - Assembling Perimeter Trim
10
INSTALLATION
Continued
Set Screws
Top
Trim
Mitered
Edge
Slot
SuperiorFireplaces.us.com
Assembled Trim
Figure 7 - Attaching Perimeter Trim to Fireplace
INSTALLATION CLEARANCES
WARNING: Maintain the minimum
clearances. If you can, provide greater
clearances from fl oor, ceiling and
adjoining wall.
Carefully follow the instructions below. This will
ensure safe installation.
Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling
A. Clearances from the side of the fi replace cabinet
to any combustible material and wall should
follow diagram in Figure 8.
Example: The face of a mantel, bookshelf, etc.
is made of combustible material and protrudes
3-1/2" from the wall. This combustible material
must be 4" from the side of the fi replace open-
ing (see Figure 8).
B. Clearances from top of fi replace opening to
ceiling should not be less than 42".
Trim
Hanging
Screws
Hanging
Notches on
Trim
126868-01D