8.

BACKUP FUNCTION

(ONLY WHEN THE BACKUP MASTER IS CONNECTED)
(1) Function
By connecting the backup master terminal (BM), the various files stored in the master terminal
(M) can be backed up.
The terminal assigned to ID No. 2 will function as a backup master terminal (BM). By pro-
gramming ID No. 2 in the terminal connection table and downloading this data to each termi-
nal, the system will function as a system in which the backup master terminal (BM) is con-
nected.
By changing terminal ID from 2 to 1, the backup master terminal (BM) will function as the
master terminal (M).
<Files to be Backed Up>
Cashier Table
(When the floating cashier system is used)
Customer File (Check Track) Table
PC Transmission Information Table
NOTE:
The tables (center files) managed by the master terminal (M) and used by each
terminal via inquiries and PC transmission information tables are backed up.
Sales data is backed up on a real-time basis.
When sales data of the master terminal (M) is updated, sales data of the backup master
terminal (BM) is updated at the same time.
Backup data check function:
Correspondence between the center files and backup data is checked every certain period of
time.
Program data
Sales data
Program data
Sales data
Program data
– 28 –