Drain Piping Work - Toshiba RAV-SM560XT-E Service Manual

Under ceiling / console type
Hide thumbs Also See for RAV-SM560XT-E:
Table of Contents

Advertisement

9-6. DRAIN PIPING WORK

9-6-1. Drainage
1. Run the Drain hose sloping downward.
NOTE :
• The hole should be made at a slight downward slant on the outdoor side.
Under Ceiling Installation
In case of upward drainage from the unit, (Under Ceiling Installation), it is necessary to use the Drain pump
kit of optional part.
1. Do not raise the Drain hose.
2. Do not put the Drain hose into water.
3. Do not form the Drain hose into a wave shape.
4. Do not put the Drain hose end in the drainage ditch.
2. Open the louver manually and put some water into it.
Then check the flow of water from the Drain hose.
3. When connecting the Extension drain hose; insulate the connecting part of Extension drain hose with the
Pipe shield.
Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping. (Provide by customer)
50 mm or more
Fig. 9-6-1
NOTICE
CAUTION
Fig. 9-6-2
Pipe shield
Inside the room
Drain hose
Fig. 9-6-3
CAUTION
– 36 –
Console Installation
50 mm or more
Extension drain hose