Drain Piping Work - Toshiba RAV-SM561KRT-E Installation Manual

Hide thumbs Also See for RAV-SM561KRT-E:
Table of Contents

Advertisement

5

DRAIN PIPING WORK

Piping and drain hose installation
In case of right-side exit
• Cut out the knockout portion by the slits with a knife or pair of wire cutters as necessary.
In case of downward pipe exit
• Cut out the knockout portion by the slits with a knife or pair of wire cutters as necessary.
Piping via left-hand connection
Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid
exceeding 43 mm above the wall surface, the indoor unit could be unstable when set on the wall. When bending the
connecting pipes, always use a suitable bending tool to avoid damaging the pipes.
Bend the connection pipe within a radius of 30 mm.
To connect the pipe after installation of unit (figure)
Outward form of indoor unit
If the pipe is bent incorrectly, the indoor unit could be unstable on the wall.
After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and
insulate as necessary.
3
Toshiba 1074007701(01EN)_P01-10
Slit (Body right)
Slit (Body right)
465 mm
365 mm
Gas side
R 30 mm
Use the handle of a screwdriver, etc.
7
(To the front of the flare)
Liquid side
NOTE
6
7/16/04, 13:30
TOSHIBA RAV-SM561KRT-E (EN) 1074007701
EN