Specification Of Electrical Parts - Toshiba RAV-SM560XT-E Service Manual

Under ceiling / console type
Hide thumbs Also See for RAV-SM560XT-E:
Table of Contents

Advertisement

5-1. Indoor Unit
No.
Parts name
1
Fan motor (for indoor)
2
Grille motor
3
Thermo. sensor (TA-sensor)
4
Heat exchanger sensor (TC-sensor)
5
Heat exchanger sensor (TCJ-sensor)
5-2. Outdoor Unit (RAV-SM560AT-E)
No.
Parts name
1
Fan motor
2
Compressor
3
Reactor
4
Outdoor temp. sensor (To-sensor)
5
Heat exchanger sensor (Te-sensor)
6
Suction temp. sensor (Ts-sensor)
7
Discharge temp. sensor (Td-sensor)
8
Fuse (Switching power (Protect))
9
Fuse (Inverter, input (Current protect)
10
4-way valve solenoid coil
11
Compressor thermo. (Protection)
5-3. Outdoor Unit (RAV-SM800AT-E)
No.
Parts name
1
Fan motor
2
Compressor
3
Reactor
4
Outdoor temp. sensor (To-sensor)
5
Heat exchanger sensor (Te-sensor)
6
Suction temp. sensor (Ts-sensor)
7
Discharge temp. sensor (Td-sensor)
8
Fuse (Switching power (Protect))
9
Fuse (Inverter, input (Current protect)
10
4-way valve solenoid coil
11
Compressor thermo. (Protection)

5. SPECIFICATION OF ELECTRICAL PARTS

Type
AFP-220-50-4A
MP35EA12
550 mm
∅6 mm, 500 mm
∅6 mm, 500 mm
Type
ICF-140-43-1
DA130A1F-23F
CH-57
STF-0108G
US-622
Type
ICF-140-63-1
DA220A2F-20L
CH-47
DKV-M0ZS743B0
US-622
– 12 –
Specifications
Output (Rated) 50 W, 220 – 240 V
DC 12 V
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
Specifications
Output (Rated) 40 W
3 phase, 4P, 1100 W
1=10 mH, 16A
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
50 kΩ at 25°C
T3.15 A, AC 250 V
25 A, AC 250 V
ON : 90 ± 5°C, OFF : 125 ± 4°C
Specifications
Output (Rated) 63 W, 220 – 240 V
3 phase, 4P, 1600 W
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
50 kΩ at 25°C
T3.15 A, AC 250 V
25 A, AC 250 V
ON : 90 ± 5°C, OFF : 125 ± 4°C