Maintaining and repairing the device

5.3 Resetting the device to factory settings

5.3
Resetting the device to factory settings
The reset button is used to reset the device to factory settings, for example, when the
IFP1900 INOX PRO can no longer communicate with the IPC for a longer period.
During the reset to factory settings, the IP address of the IFP1900 INOX PRO, for example,
is reset to the default value "192.168.1.2".
Procedure
1. Switch off the device's power supply.
2. Press the reset button with a suitable tool and keep the reset button pressed.
3. Switch on the device's power supply and keep the reset button pressed for an additional
10 seconds.
During this the two LAN LEDs are deactivated briefly.
5.4

Repair

In case of repair, the device must be shipped to the Return Center in Erlangen. Repairs may
only be carried out at the Return Center in Erlangen.
The device described in this document is covered by the conditions of repair and return of
equipment, as follows:
1. You return the defective device to the returned goods center. The address is:
Siemens AG
c/o Geis Service GmbH, Tor 1-4
Kraftwerkstraße 25a
91056 Erlangen
Germany
2. After it has been repaired, the device is returned to you. A new device will not be supplied
in exchange.
Depending on the work necessary to repair the device, the Center may decide to give you a
credit note. In this case, it is your responsibility to order a new device.
For additional information, refer to the Internet at Spare parts and repairs
(http://support.automation.siemens.com/WW/view/en/16611927).