Fuse Replacement

!
!
CAUTION: The fuse protects the transformer from overload
and subsequent damage due to a short circuit condition.
For continued protection against the risk of controller damage
or fire, replace only with a fuse of the same type.
Ensure power is OFF prior to removing/replacing the fuse.
1. Disconnect power to the controller.
2. Carefully remove the blown fuse from the PC board.
3. Replace with spare fuse (clipped to PCB) or
4. Restore power to the controller.
Specifications
Mechanical
• Cabinet (overall): 10.5" H x 17" W x 6" D
• Wiring Conduit Provisions:
Field - 2.5"/ 3" (64mm/76mm)
Power - 0.50"/.75" (12.7mm/19mm)
Aux. - 0.50"/1" (12.7mm/25.4mm)
• Operating Temperature Range: 32°F to 140°F (0°C to 60°C)
• Storage Temperature Range: -22°F to 149°F (-30°C to 65°C)
Electrical
• Input: 120 VAC, 50/60 Hz, 0.5A (24 W max.)
Output (per station): 24 VAC, 50/60 Hz, 0.5A (12 VA max.)
Output (total): 24 VAC, 50/60 Hz, 1.5A (36 VA max.)
• Master Valve/Pump Start Relay Output: 24 VAC, 0.5A
• Rain Sensor Compatability: Normally-closed
• Flow Sensor Compatability: Toro TFS Series or
Data Industrial IR Series
• Fuse: 250V, 2A, Slo-Blo
250V, 2A
(Slo-Blo).