EN
Operating instructions...................... pages 1 to 8
Translation of the original operating instructions
Vous trouverez la version
FR
actuelle du mode d'emploi
dans votre langue nationale
officielle sur l'Internet,
www.schmersal.net.
U vindt de huidige versie van
NL
de gebruikshandleiding in uw
officiële landstaal op het
Internet, www.schmersal.net.
EU公用語で書かれた最新の
JP
取扱説明書は、インターネッ
(www.schmersal.net)からダウ
ンロードできます。
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.5 Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8.6 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Encontrará el manual de
ES
instrucciones actual en su
idioma oficial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lingua
ufficiale UE) è scaricabile in
Internet all'indirizzo
www.schmersal.net.
SRB 202CS / SRB 202CS/T / SRB 202CA/T /
SRB 202CA/QT / SRB 202CA / SRB 202CA/Q
1 About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The
operating instructions must be available in a legible condition and
a complete version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instructions
manual, the country-specific installation standards as well as all prevailing
safety regulations and accident prevention rules.
Further technical information can be found in the Elan
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is provided
without liability und is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of inadequate or improper use or manipulations of the
safety-monitoring module, personal hazards or damage to ma-
chinery or plant components cannot be excluded. The relevant
requirements of the standard EN 1088 must be observed.
EN
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 202CS/T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SRB 202CS/T

  • Page 1: Table Of Contents

    Operating instructions SRB 202CS / SRB 202CS/T / SRB 202CA/T / Safety-monitoring module SRB 202CA/QT / SRB 202CA / SRB 202CA/Q 1 About this document 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety-monitoring module.
  • Page 2: Exclusion Of Liability

    Operating instructions SRB 202CS / SRB 202CS/T / SRB 202CA/T / Safety-monitoring module SRB 202CA/QT / SRB 202CA / SRB 202CA/Q 1.7 Exclusion of liability 2.4 Technical data We shall accept no liability for damages and malfunctions resulting from General data...
  • Page 3: Safety Classification

    Operating instructions SRB 202CS / SRB 202CS/T / SRB 202CA/T / Safety-monitoring module SRB 202CA/QT / SRB 202CA / SRB 202CA/Q Outputs 4 Electrical connection Number of safety contacts: Number of auxiliary contacts: 4.1 General information for electrical connection Switching capacity of the 13-14;...
  • Page 4: Set-Up And Maintenance

    Operating instructions SRB 202CS / SRB 202CS/T / SRB 202CA/T / Safety-monitoring module SRB 202CA/QT / SRB 202CA / SRB 202CA/Q 24 VDC Due to the operating principle of the electronic fuse, the customer must check that no hazard is caused by an unexpected restart in circuits without reset button (automatic reset).
  • Page 5: Start Configuration

    Fig. 6 left = switch-off level 1 Dual-channel guard door monitoring circuit with interlocking right = switch-off level 2 (SRB 202CA/T, SRB 202CS/T and SRB 202CA/QT) device to EN 1088 (Fig. 12) • With at least one positive-break position switch Automatic start (see Fig.
  • Page 6: Actuator Configuration

    Operating instructions SRB 202CS / SRB 202CS/T / SRB 202CA/T / Safety-monitoring module SRB 202CA/QT / SRB 202CA / SRB 202CA/Q 8.3.3 Sensor configuration 8.4 Actuator configuration Dual-channel control of magnetic safety switches to EN 60947-5-3 Single-channel control (see Fig. 15) (see Fig.
  • Page 7: Flowcharts

    Operating instructions SRB 202CS / SRB 202CS/T / SRB 202CA/T / Safety-monitoring module SRB 202CA/QT / SRB 202CA / SRB 202CA/Q 8.5 Flowcharts SRB 202CA/T, SRB 202CS/T, SRB 202CA/QT see Fig. 18 SRB 202CA, SRB 202CS, SRB 202CA/Q see Fig. 17 Fig.
  • Page 8: Ec Declaration Of Conformity

    Operating instructions SRB 202CS / SRB 202CS/T / SRB 202CA/T / Safety-monitoring module SRB 202CA/QT / SRB 202CA / SRB 202CA/Q Appendix 8.6 EC Declaration of conformity EC Declaration of conformity Translation of the original declaration of conformity Elan Schaltelemente GmbH & Co. KG Im Ostpark 2 ·...

This manual is also suitable for:

Srb 202csSrb 202ca/tSrb 202ca/qtSrb 202caSrb 202ca/q