Countertop Requirements; Installation Procedure; Prepare Installation Space; Technical Data - Gaggenau VG 231 CA Installation Instructions Manual

Gas wok
Table of Contents

Advertisement

Available languages

Available languages

Countertop Requirements

9
WARNING
To reduce the risk of ignition of surrounding
combustible materials, install at least 6" (150 mm)
from both sidewalls and at least 2" (51 mm) from
the rear wall.
The countertop must be level and horizontal. The
stability of the countertop must be maintained after the
cut-out has been made.

Technical Data

Total connected load electric: 0.8 VA
Gas
Pressure
Nozzle, full burn, outer
C
Nozzle, low burn, outer 79
A
D Nozzle, full burn, inner
B Nozzle, low burn, inner 42
Air gap adjustment, outer 2 mm
Total connected load
Total consumption
8
Natural Gas
LPG (Propane)
6" water
10" water
column
column (2.5 kPa)
(1.5 kPa)
173
110 A
57
60
42
31
0 mm
18,800 BTU/h
17,000 BTU/h
(5.5 kW)
(5 kW)
0.52 m³/h
364 g/h

Installation Procedure

Prepare Installation Space

Create the cut-out in the countertop for one or several
Vario appliances according to the installation diagram.
The angle of of the cut surface to the countertop must
be 90°.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat-resistant manner.
Some solid surface countertops require special
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
Observe minimum distance between appliance
underside and furniture parts of
When installing multiple Vario appliances:
account space requirement for VV 200 connection strip
between the appliances. Appliances can also be
installed in individual cut-outs, bearing in mind a
minimum distance between the appliances of 1
(40 mm).
I n s t a l la t i o n P r o c e d u r e
P r e p a r e I n s t a l la t i o n S p a c e
3
/
" (10 mm).
8
Take into
/
"
9
16

Advertisement

Table of Contents
loading

Table of Contents