TROUBLESHOOTING GUIDE
PROBLEM
12. Control valve fails to
draw in regenerant
13. Water running to
drain
14. E1, Err – 1001,
Err – 101 =
Control unable
to sense motor
movement
15. E2, Err – 1002, Err –
102 = Control valve
motor ran too short
and was unable to
find the next cycle
position and stalled
CAUSE
A . Injector is plugged
B . Faulty regenerant piston
C . Regenerant line connection leak
D . Drain line restriction or debris cause excess
back pressure
E . Drain line too long or too high
F . Low water pressure
A . Power outage during regeneration
B . Damaged seal/stack assembly
C . Piston assembly failure
D . Drive cap assembly not tightened in properly
A . Motor not inserted full to engage pinion,
motor wires broken or disconnected
B . PC board not properly snapped into drive bracket
C . Missing reduction gears
A . Foreign material is lodged in control valve
B . Mechanical binding
C . Main drive gear too tight
D . Improper voltage being delivered to PC board
CORRECTION
A . Remove injector and clean or replace
B . Replace regenerant piston
C . Inspect regenerant line for air leak
D . Inspect drain line and clean to
correct restriction
E . Shorten length and or height
F . Check incoming water pressure – water
pressure must remain at minimum of 25 psi
A . Upon power being restored control will finish
the remaining regeneration time . Reset time of
day . If PC board has battery back up present
the battery may be depleted . See front cover
and drive assembly drawing for instructions .
B . Replace seal/stack assembly
C . Replace piston assembly
D . Retighten the drive cap assembly
A . Disconnect power, make sure motor is fully
engaged, check for broken wires, make sure
two pin connector on motor is connected to the
two pin connection on the PC board labeled
MOTOR . Press NEXT and REGEN buttons for
3 seconds to resynchronize software with piston
position or disconnect power supply from PC
board for 5 seconds and then reconnect .
B . Properly snap PC board into drive bracket and
then Press NEXT and REGEN buttons for 3
seconds to resynchronize software with piston
position or disconnect power supply from PC
board for 5 seconds and then reconnect .
C . Replace missing gears
A . Open up control valve and pull out piston
assembly and seal/stack assembly for
inspection . Press NEXT and REGEN buttons for
3 seconds to resynchronize software with piston
position or disconnect power supply from PC
board for 5 seconds and then reconnect .
B . Check piston and seal/stack assembly, check
reduction gears, check drive bracket and main
drive gear interface . Press NEXT and REGEN
buttons for 3 seconds to resynchronize software
with piston position or disconnect power supply
from PC board for 5 seconds and then reconnect .
C . Loosen main drive gear . Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds
and then reconnect .
D . Verify that proper voltage is being supplied .
Press NEXT and REGEN buttons for 3 seconds
to resynchronize software with piston position
or disconnect power supply from PC board for
5 seconds and then reconnect .
14