PROBLEM
7. Control valve does not
regenerate automatically
but does when the
correct button(s) is
depressed and held.
For time clock valves the
buttons are s & t.
For all other valves the
button is REGEN.
8. Hard or untreated
water is being
delivered
9. Control valve uses too
much regenerant
10. Residual regenerant
being delivered to
service
11. Excessive water in
regenerant tank
CAUSE
A . Bypass valve in bypass position
B . Meter is not connected to meter connection on
PC board
C . Restricted/stalled meter turbine
D . Incorrect programming
E . Meter wire not installed securely into three
pin connector
F . Defective meter
G . Defective PC board
A . Bypass valve is open or faulty
B . Media is exhausted due to high water usage
C . Meter not registering
D . Water quality fluctuation
E . No regenerant or low level of regenerant in
regenerant tank
F . Control fails to draw in regenerant
G . Insufficient regenerant level in regenerant tank
H . Damaged seal/stack assembly
I . Control valve body type and piston type
mix matched
J . Fouled media bed
A . Improper refill setting
B . Improper program settings
C . Control valve regenerates frequently
A . Low water pressure
B . Incorrect injector size
C . Restricted drain line
A . Improper program settings
B . Plugged injector
C . Drive cap assembly not tightened in properly
D . Damaged seal/stack assembly
E . Restricted or kinked drain line
F . Plugged backwash flow controller
G . Missing refill flow controller
CORRECTION
A . Turn bypass handles to place bypass in
service position
B . Connect meter to three pin connection labeled
METER on PC board
C . Remove meter and check for rotation or
foreign material
D . Check for programming error
E . Verify meter cable wires are installed securely
into three pin connector labeled METER
F . Replace meter
G . Replace PC board
A . Fully close bypass valve or replace
B . Check program settings or diagnostics for
abnormal water usage
C . Remove meter and check for rotation or
foreign material
D . Test water and adjust program
values accordingly
E . Add proper regenerant to tank
F . Refer to Troubleshooting Guide number 12
G . Check refill setting in programming . Check
refill flow control for restrictions or debris and
clean or replace
H . Replace seal/stack assembly
I . Verify proper control valve body type and
piston type match
J . Replace media bed
A . Check refill setting
B . Check program setting to make sure
they are specific to the water quality and
application needs
C . Check for leaking fixtures that may be
exhausting capacity or system is undersized
A . Check incoming water pressure – water
pressure must remain at minimum of 25 psi
B . Replace injector with correct size for
the application
C . Check drain line for restrictions or debris
and clean
A . Check refill setting
B . Remove injector and clean or replace
C . Retighten the drive cap assembly
D . Replace seal/stack
E . Check drain line for restrictions or debris and
or unkink drain line
F . Remove backwash flow controller and clean
or replace
G . Replace refill flow controller
13