3.2 Charger Mounting

• Install the MAX Charger in the horizontal upright position. The charger is furnished with
mounting brackets which provide adequate clearance for under chassis airflow. The charger
requires under chassis airflow for proper cooling.
3.3 Routing and Connecting Battery Charger Output Cables
WARNING
Safety goggles
should be worn
when working with
or near batteries
WARNING
Battery connections
must be able to carry a
minimum of 50 amps.
MAX Charger
Output Signal notifying
that AC power is Present

F 2 Figure 3.4-1 Max Battery Charger Wiring Diagram

Max Battery Charger
This Charger is designed for 24 VDC applications only. If
connected to other than 24V system, damage will result.
1. Connect the Max Charger's RED cable to the battery's
positive (+) terminal and the BLACK cable to the
Battery's negative (-) terminal.
2. Install a fuse in line with the positive battery source to
the charger. Size fuse at an 80Amp minimum to a 150A
maximum.
3. Battery cable connections must be clean and secure to
minimize electrical resistance for optimum performance.
4. Route and secure charger DC cables away from Hot and
Sharp surfaces and components.
5. "AC power is Present" mating connection is a
Delphi Weather-Pack 12015791 with terminal selected
per the gauge wire required for application.