USER MANUAL
Operation: Temporary (override) modes
Summer mode
Summer mode, when active, will stop the supply fan and only the exhaust fan will be in op-
eration. Fresh air supply will in this case be ensured by opening windows, doors e.g.
NB: Summer mode will be disabled automatically, when the outdoor temperature drops
below 14°C.
Fireplace mode
Activating fireplace can be used, while you lit the fire in the fireplace. The unit will then create
overpressure for 7 minutes, in order to prevent smoke in the living area. If fireplace mode is
not deactivated manually, it will automatically stop after 7 minutes.
NB: Fireplace mode is only activated as long as the supply air temperature is above 9 °C.
Long press (5 sec.) - activates/ deactivates summer mode
Summer mode active is indicated by a flashing light in corresponding LED
Long press (5 sec.) - activates/deactivates fireplace mode.
Fireplace mode active is indicated by a flashing of the 3 fan speed LEDs
11