  • Page 1 Keysight ZA0060A Custom IoT Device Functional Test Solution For Multi-up Configuration Quick Start Guide...
  • Page 2: Safety Information

    227.7103-5 (c), as applicable in any Do not proceed beyond a WARNING technical data. notice until the indicated conditions are fully understood and met. Keysight ZA0060A Custom IoT Device Functional Test Solution Quick Start Guide...
  • Page 3: Safety Symbols

    Standby supply. Unit is not completely connected from AC mains when Frame or chassis (ground) terminal switched off Equipment protected throughout by Protective earth (ground) terminal double insulation or reinforced insulation Keysight ZA0060A Custom IoT Device Functional Test Solution Quick Start Guide...
  • Page 4: Safety Considerations

    Only qualified, service-trained personal who are aware of the hazards involved should remove instrument covers. Always disconnect the power cable and any external circuits before removing the instrument cover. Keysight ZA0060A Custom IoT Device Functional Test Solution Quick Start Guide...
  • Page 5 Do Not Modify the Instrument Do not install substitute parts or perform any unauthorized modification to the product. Return the product to a Keysight Sales and Service Office for service and repair to ensure that safety features are maintained. In Case of Damage...
  • Page 6: Safety And Regulatory Information

    – Canada: CAN/CSA-C22.2 No.61010-1-12; CAN/CSA-C22.2 No. 61010-2-030-12 – USA: ANSI/UL Std. No. 61010-1:2012; ANSI/UL Std No.61010-2-030:2012 EMC regulation – IEC 61326-1:2012 / EN 61326-1:2013 – Canada: ICES/NMB-001:2006 – Australia/New Zealand: AS/NZS CISPR 11:2011 Keysight ZA0060A Custom IoT Device Functional Test Solution Quick Start Guide...
  • Page 7: Regulatory Markings

    This instrument complies with the WEEE Directive (2002/96/EC) marking requirement. This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste. Keysight ZA0060A Custom IoT Device Functional Test Solution Quick Start Guide...
  • Page 8: Waste Electrical And Electronic Equipment (Weee) Directive 2002/96/Ec

    The affixed product label is as shown below. Do not dispose in domestic household waste. To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml for more information. Keysight ZA0060A Custom IoT Device Functional Test Solution Quick Start Guide...
  • Page 9: Sales And Technical Support

    Sales and Technical Support To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites: – www.keysight.com/find/X8711A (product-specific information and support, software and documentation updates) – www.keysight.com/find/assist (worldwide contact information for repair and service)
  • Page 10 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight ZA0060A Custom IoT Device Functional Test Solution Quick Start Guide...
  • Page 11: Table Of Contents

    Fail to switch RF path(s) with error code -2 ....39 No valid BLE/WLAN/Zigbee option license found. For license request Keysight ZA0060A Quick Start Guide...
  • Page 12 Keysight Technologies Sales & Support..40 Could not create '<Test step>': License required: KS8330xA or KS8330xB ......... . . 40...
  • Page 13: Introduction

    Custom IoT Device Functional Test Solution Quick Start Guide Introduction The Keysight ZA0060A is a custom solution based on the X8711A IoT device functional test solution. It is an over-the-air signaling tester that enables you to test your IoT device’s transmitter and receiver easily and effectively. It is as simple...
  • Page 14: To Prepare Instrument For Use

    – Keysight 34972A LXI Data Acquisition / Switch Unit – Keysight 34999B RF Module – Keysight U1810B USB Coaxial Switch that comes with a N-type female to female adaptor (1250-3274), a USB cable (8121-0506) and three RF cables. – Power cord –...
  • Page 15: Hardware Configuration

    Connect the N-type female to female adapter (P/N 1250-3274) to the common port of U1810B before connecting the RF cable from the adapter to 5 (RFIO Port) of 34999B. Do not remove the terminator at 4 (AuxIO Port). Keysight ZA0060A Quick Start Guide...
  • Page 16 34972A. Allow 15 seconds after powering on the 34972A for your PC to detect the instrument and its VISA address. Refer to the U1810B Operating and Service Manual for more information on NOTE troubleshooting and calibration. Keysight ZA0060A Quick Start Guide...
  • Page 17: Software Installation

    Software Installation The Install wizard is a centralized application that contains necessary installers and software packages for the ZA0060A solution. Download the latest Install wizard to access the new releases of the software packages. 1 Download and install X8711A & ZA0060A Install wizard from www.keysight.com/find/ZA0060A-installwizard.
  • Page 18 34999 Utility application is a compulsory software that will be selected by default when it is not installed in your PC. 5 When the status reflects the latest version installed, you may close the Install wizard. Next, proceed to redeem your licenses. Keysight ZA0060A Quick Start Guide...
  • Page 19: Tap And Measurement Suite License Redemption

    1 Refer to the email or printed Keysight License Entitlement Certificate for instructions on how to redeem your license. 2 Log in to Keysight Software Manager (KSM) using your myKeysight account at www.keysight.com/find/softwaremanager. First time users need to create a new account and add the Keysight Software Manager capability.
  • Page 20 7 Select a host to assign your licenses. Depending on the type of license(s) selected, you are required to provide any one of the following information. a For node-locked licenses, click ‘Add a new Keysight License Manager Host ID host’ and enter the Host ID.
  • Page 21 9 You should see the page below. Click Yes to assign more license(s) to other hosts. Otherwise, click No and followed by Continue. 10 Enter your email address and click Submit. You should receive an email shortly. For more information, view the Keysight Software Manager Help File. NOTE Keysight ZA0060A Quick Start Guide...
  • Page 22: Tap And Measurement Suite License Installation

    Click the tools icon (1) followed by Install License File (2). b Locate the local copy of the License file (.lic) and click Open. c Successful license installation will be listed as below. 4 Repeat steps 1 through 3 to install more than one licenses. Keysight ZA0060A Quick Start Guide...
  • Page 23: Usb Portable License

    1 You will receive an email for the license file(s). Copy the attachment with the .lic extension to your PC. 2 Download and install Keysight License Manager 6 at www.keysight.com/find/ KLM6. Double-click the installer and follow the instructions to complete installation.
  • Page 24 5 Launch Keysight License Manager 6 from your computer’s Start menu. Click the Add/remove a license to your local machine. 6 Click the Add a license to this floating license server to be used by other machines option. Keysight ZA0060A Quick Start Guide...
  • Page 25 7 Click Browse and browse to the location of the license File. Click Next. When you are prompted to run a service in a pop-up window, click Yes. 8 You should see the image below the licensing actions were completed successfully. Click Done. Keysight ZA0060A Quick Start Guide...
  • Page 26 You may need to click Refresh if it is not listed. In this example, KS83301B is successfully installed in the KLM 6. 10 Go to the Windows menu, search for 'Edit the system environment variables' and press Enter to view the window below. Click Environment variables. Keysight ZA0060A Quick Start Guide...
  • Page 27 Ensure that only one of LM_LICENSE_FILE variable is created in either User or NOTE System variables. 12 Click New to create the LM_LICENSE_FILE variable and enter the information as shown below. Click OK and you may close all the windows related to environmental variables. Keysight ZA0060A Quick Start Guide...
  • Page 28 BLE measurement suite in TAP with the KS83301B license installed. 14 Repeat these steps on each machine on which you plan to use the USB portable license. View the Keysight Licensing Administrator’s Guide for more information. NOTE Keysight ZA0060A Quick Start Guide...
  • Page 29: Getting Started: Iot Device Test Add-Ons Package

    5 Signaling test plans on two devices under test (DUT). 1 Launch Keysight TAP. You may turn on the 34972A and allow 15 seconds for your PC to detect the connection via Keysight Connection Expert. 2 Ensure that you have selected and installed the IoT Device Test Add-Ons...
  • Page 30 Rad io step. 6 Right-click the 1.0 Bluetooth 5 Device Discovery test step and click Copy. 7 Right-click the 1.0 Bluetooth 5 Device Discovery and click Paste to place the ® second Bluetooth 5 Signaling test plan. Keysight ZA0060A Quick Start Guide...
  • Page 31 9 Click and drag test steps to rearrange the steps as shown below. 10 Next, configure the Step Settings for the two USB Coaxial Switch Steps. a Select U1810B or U1816A model from the drop-down list. Keysight ZA0060A Quick Start Guide...
  • Page 32 Signaling test plans on two DUTs. If you intend to run two test plans that uses different radios, place the USB Coaxial Switch Step at the start of the first and second test plan as shown below. Test Plan 1 Test Plan 2 Keysight ZA0060A Quick Start Guide...
  • Page 33 13 Once the test is complete, you can view the results at the ‘Step Settings’ tab for each test step. For those who have set up the Results Listener plug-ins, find your recorded results in the default directory C:\Program Files\Keysight\Tap8\Results to open each file in Microsoft Excel. Keysight ZA0060A Quick Start Guide...
  • Page 34: Procedure To Use Usb Coaxial Switch Step (Method 2)

    3 Drag the Sweep Loop test step and place it after 0 Initialize Bluetooth 5 Radio. Ensure the USB Coaxial Switch and the remaining test steps are placed as the child steps of Sweep Loop. Keysight ZA0060A Quick Start Guide...
  • Page 35 7 Once the test is complete, you can view the results at the ‘Step Settings’ tab for each test step. For those who have set up the Results Listener plug-ins, find your recorded results in the default directory C:\Program Files\Keysight\Tap8\Results to open each file in Microsoft Excel. Keysight ZA0060A Quick Start Guide...
  • Page 36: Procedure To Use 34901 Measurement

    – Thermocouple: B, E, J, K, N, R, S, T – Thermistor: 2252, 5000, 10000 – 2-wire and 4-wire RTD: 85, 91 – Resolution: Default, Maximum, Minimum, and Custom. For custom resolution, enter the resolution value in °C in the entry box. Keysight ZA0060A Quick Start Guide...
  • Page 37 For your information, these are the commands used to perform measurements in the 34901A Measurement test step. a MEASure:TEMPerature? {TCouple|RTD|FRTD|THERmistor},{<type>},1,{<resolution>|MIN |MAX|DEF}, (@<scan_list>) b MEASure:VOLT:DC? {<range>|AUTO},{<resolution>|MIN|MAX|DEF}, (@<scan_list>) c MEASure:RESitance? {<range>|AUTO},{<resolution>|MIN|MAX|DEF}, (@<scan_list>) d MEASure:FRESitance? {<range>|AUTO},{<resolution>|MIN|MAX|DEF}, (@<scan_list>) Refer to 34901A Quick Reference Guide 34970A User’s Guide. Keysight ZA0060A Quick Start Guide...
  • Page 38: Record And Export Data

    4 Click OK to return to your test plan. 5 When your test plan completes, find your recorded results in the default directory C:\Program Files\Keysight\Tap8\Results to open each file in Microsoft Excel. Keysight ZA0060A Quick Start Guide...
  • Page 39: Troubleshooting And Error Messages

    – Check the connection of the USB cable to your PC and the switch is secure. – When the USB coaxial switch is plugged in, you should see the green LED light – Ensure that the power supply is functioning well. – Replace the faulty cable with a new one. Keysight ZA0060A Quick Start Guide...
  • Page 40 Depending on the options purchased, this error message indicates that the respective radio options are not enabled on your 34999B boards. You will need to purchase the license(s) to use by contacting your local Keysight representative. Once you have purchased your license(s), refer to the instructions in the entitlement certificate to redeem your license(s).
  • Page 41 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight ZA0060A Quick Start Guide...
  • Page 42 This information is subject to change without notice. Always refer to the English version at the Keysight website for the latest revision. © Keysight Technologies 2019 Edition 1, December 2019 Printed in Malaysia *ZA0060-90001* ZA0060-90001 www.keysight.com...