6. CONNECTION TO THE CHIMNEY

For safety reasons the door of the hearth can be open only during the fuel loading. The hearth must remain
closed during the operation and the periods of non-use.
The chimney stove is equipped with an upper and rear smokes exhaust for (see on pages 43 for the
assembly of particular components in order to change the smoke exhaust).
The junction pipe for the connection to the chimney must be the shortest possible and the junction points of
the single pipes must be hermetic. The connection to the chimney must be performed with stable and
strong pipes (we recommend a thickness of 2 mm). The pipe for smokes exhaust must be fixed
hermetically to the chimney. The diameter inside the connection pipe must correspond to the external
diameter of the smokes exhaust small trunk of the stove. This is ensured by pipes according to DIN 1298.
ATTENTION: Eventual flammable pieces in the area of 20 cm round the connection pipes must be
changed with fireproof and not sensitive to heat materials.
For a good operation of the equipment it is essential that in the installation place it is introduced sufficient
air for combustion. This means that, through suitable openings, air must recirculate for the combustion,
even with doors and windows closed (see chapter 7).
The depression on the chimney should be 10 – 12 Pa (=1.0 – 1.2 mm of water column). The measurement
must be done always with the equipment hot (rating calorific value). When the depression exceeds 17 PA
(1.7 mm of water column) it is necessary to reduce the same with the installation of an additional flue
adjuster (butterfly valve) on the exhaust pipe or in the chimney.

7. AIR ENTRANCE INTO THE INSTALLATION PLACE DURING COMBUSTION

As the stoves take their combustion air from the installation place, it is essential that a sufficient quantity of
air is introduced in the installation room itself.
In case of tight doors and windows (for example houses built according to the energy saving criteria) it is
possible that the air entrance is not guaranteed, compromising the draught, the welfare and the security of
the people. It is necessary to guarantee a further air entrance through an external air intake, to be
positioned in the nearby of the appliance or through air connection towards outside or a near ventilated
room, with the exception of thermal units place or garages (FORBIDDEN).
22
CHIMNEY CAPS - DISTANCES AND POSITIONING
Distance between the roof
ridge and the stack
A (m)
< 1.85 m
> 1.85 m
< 1.50 m
> 1.50 m
< 1.30 m
> 1.30 m
< 1.20 m
> 1.20 m
UNI 10683/98
Minimum height of the stack
(measured from the outlet)
0.50 m
1.00 m
0.50 m
1.30 m
0.50 m
2.00 m
0.50 m
2.60 m
Instructions for installation, use and maintenance – EN – Rev.04
GIULIETTA – ISETTA-07 – ISOTTA-07
H (m)
above the roof ridge
from the roof
above the roof ridge
from the roof
above the roof ridge
from the roof
above the roof ridge
from the roof