Nice mindy A02 Instructions And Warnings For The Fitter

Nice mindy A02 Instructions And Warnings For The Fitter

Advertisement

Quick Links

Control unit
mindy A02
Instructions and warnings for the fitter
Istruzioni ed avvertenze per l'installatore
Instructions et recommandations pour l'installateur
Anweisungen und Hinweise für den Installateur
Instrucciones y advertencias para el instalador
Instrukcje i ostrzeøenia do instalacji
Aanwijzingen en aanbevelingen voor installatie en gebruik

Advertisement

Table of Contents
loading

Summary of Contents for Nice mindy A02

  • Page 1 Control unit mindy A02 Instructions and warnings for the fitter Istruzioni ed avvertenze per l’installatore Instructions et recommandations pour l’installateur Anweisungen und Hinweise für den Installateur Instrucciones y advertencias para el instalador Instrukcje i ostrzeøenia do instalacji Aanwijzingen en aanbevelingen voor installatie en gebruik...
  • Page 2: Product Description

    1) Product description The Mindy A02 control unit enables the control of single-phase asynchronous motors powered by the electrical mains, with “COMMON” “OPEN” “CLOSE” type connections. It is designed for the automation of shutters, overhead garage doors, gates, rolling shutters or awnings. The control unit incorporates a radio receiver operating at a frequency of 433.92 MHz, which is compatible with the following types of transmitters:...
  • Page 3 2.1) Electrical connections Carefully follow all the connection instructions. If you An incorrect connection may cause serious damage to the have any doubts do not make experiments but consult the control unit. Do not connect multiple motors in parallel relevant technical specifications sheets which are also unless specifically required by the type of motor;...
  • Page 4 STEP-BY-STEP input This Bus enables separate control of up to 100 control units by con- Each command on this input activates the open - stop - close - stop necting them in parallel using only 2 wires. sequence. In this mode, if the command is maintained for over 3 Further information is contained in the instructions for the remote con- seconds (but less than 10), an opening manoeuvre will always be trols via “TTBUS”.
  • Page 5: Programmable Functions

    4) Programming The control unit allows you to program some parameters and select some of the functions that are described below. 4.1) Programming of the working time The “Operating Time” is the maximum time in which the control unit controls the motor until it reaches the Up or Down limit switch; the fac- tory setting or after the memory has been cancelled is approximately 120 seconds.
  • Page 6: Description Of Functions

    4.4) Description of functions Step-by-step input: An open or step-by-step command causes an inversion of the This input that normally performs the sequence “open-stop-close- manoeuvre during a closing operation. stop”, can be programmed as “open” (dip-switch 1 ON), in this case the sequence becomes “open-stop-open-stop”.
  • Page 7: Remote Memorization

    The deletion of all the data from the memory will also modify any programmed settings (working time, TTBUS address,….) and restore the control unit to the factory settings. 5) Optional accessories The Mindy A02 control unit features a connector for connection to The SMU programmer only enables the management of the SMU programmer. The programmer can be used to enter, erase, the radio control codes.
  • Page 8: Technical Characteristics

    FLO (fixed code), FLOR (rolling code) SMILO (rolling code) Maximum number of transmitters that can be memorized: Nice S.p.a reserves the right to modify its products at any time it deems necessary. EC Declaration of conformity EC Declaration of conformity with Directive 1999/5/EC...