mindy A100F
Instructions and warnings for the fitter
Istruzioni ed avvertenze per l'installatore
Instructions et recommandations pour l'installateur
Anweisungen und Hinweise für den Installateur
Instrucciones y advertencias para el instalador
Instrukcje i uwagi dla instalatora

Advertisement

Table of Contents
loading

Summary of Contents for Nice Mindy A100F

  • Page 1 A100F Instructions and warnings for the fitter Istruzioni ed avvertenze per l’installatore Instructions et recommandations pour l’installateur Anweisungen und Hinweise für den Installateur Instrucciones y advertencias para el instalador Instrukcje i uwagi dla instalatora...
  • Page 2: Table Of Contents

    A100F Contents: pag. Product description Programmable functions Description of functions Installation Mounting the A100F control unit How to… Typical system layout Electrical connections Optional accessories 2.3.1 Electrical diagram 2.3.2 Description of connections Maintenance 2.3.3 Constant resistance STOP input 2.3.4...
  • Page 3: Product Description

    1) Product description The A100F control unit enables the control of overhead garage type of automation: “Sliding / Overhead”. doors and sliding gates equipped with single-phase alternate-cur- A number of LEDs located near the inputs signal their status, while rent gearmotors. It features a system for force adjustment and a an additional LED located below the dip-switch (OK LED) signals the “constant resistance STOP”...
  • Page 4: Typical System Layout

    5. Control unit A100f In particular, please note that: • All the photocells produced by NICE feature a SYNCHRONISATION SYSTEM that eliminates the problem of interference between two pairs of photocells (please consult the photocell instructions for further details). • The “PHOTO” pair of photocells have no effect when the gate is opening, while they reverse movement when the gate is closing.
  • Page 5: Electrical Diagram

    2.3.1) Wiring diagram Radio receiver AERIAL 10 11 12 13 OVERHEAD FORCE GARAGE DOOR SLIDING GATE 2.3.2) Description of the connections The following table provides a brief description of the possible control unit output connections. Terminal Functions Description Power supply mains power supply line Flashing light Output for connecting flashing light to mains voltage (Max.
  • Page 6: Constant Resistance Stop Input

    2.3.3) Constant resistance STOP input It enables the connection to the control unit of devices with 8.2KΩ constant resistance (e.g. sensitive edges) The input measures the value of the resistance and disables the manoeuvre when the resistance is outside the nominal value The control unit is supplied with 8.2KΩ...
  • Page 7: Connecting The Photocells

    2.3.4) Connecting the photocells This control unit features a “Phototest” function designed to improve • Set Dip –Switch 10 to ON: Phototest enabled; in the future it can the reliability of the safety devices, enabling the control unit and safe- be disabled at any time by setting Dip –Switch no.
  • Page 8: Checking Connections

    2.3.5) Testing the connections The following operations entail working on live circuits; • To see whether or not the direction of rotation is correct, give a most of these run on extra-low safety voltage so they are short impulse to the Open input, and make sure that the automat- not dangerous but some contain mains voltage which ic system moves in the opening direction;...
  • Page 9: Testing

    4) Testing After the above checks and adjustments have been made, the sys- Testing is the most important part of the whole automation process. tem can be tested. Each single component, e.g. motor, emergency stop, photocells, etc., may require a specific test phase; please follow the procedures The automation system must be tested by qualified and described in the operating instructions for each component.
  • Page 10: Programmable Functions

    6) Programmable functions The control unit features a set of microswitches and a selection Some of the programmable functions are linked to jumper that allow you to activate various functions designed to make safety aspects; carefully evaluate the effects of a function the system more suitable to the needs of users and more reliable and see which function will ensure the highest possible under different operating conditions.
  • Page 11 As well as reducing the speed of the manoeuvre, the deceleration function also reduces motor torque by 70%. For systems requiring elevated torque, this decrease may cause the motor to stop immediately. Deceleration function in sliding mode At the end of an opening or closing manoeuvre due to the expiration of the Working Time the system enters a deceleration stage which lasts up to a maximum of half the Working Time, until the limit switches are reached.
  • Page 12: How To

    7) How to… Connect two control units on opposing sliding leaves • The inputs must be connected in parallel. To create an automation system working with 2 opposing sliding • As “Common” terminal for the inputs (terminal 13) you can use the leaves: one on either control unit.
  • Page 13: Disposal

    : Adjustable from 2.5 to >20 s, or from <20 to >80 s with TLM Pause Time (TP) : Adjustable from 5 to >80 sec. Dimensions; Weight : 230 x 180 h100 mm ; 2110 g. Protection class : IP 55 Nice S.p.a. reserves the right to modify its products without any notice...