6.6.
CLEANING THE AIR/OIL RADIATOR.
6.6.1.
remove upper and lower plastic shrouds to gain access to
inside the compressor.
6.6.2.
Blow compressed air through the radiator, from inside
outwards,making sure that no dirt settles inside the
compressor. (fig.12.)
7. TROUBLESHOOTING
PROBLEM
compressor not starting .
compressor stops,
thermal trip activated.
compressor stops.
To reset oil temperature trip: unscrew cap.
© Jack sealey Limited
POSSIBLE CAUSE
no mains power.
Excessive air/oil mixture
temperature.
motor overheating: motor thermal
relay activated.
fig.13
Then use pointed object to press trip button,
replace cap.
Original Language Version
fig.12
SOLUTION
check mains power, including
supply fuses and breakers.
check oil level
check that air/oil radiator is not
blocked.
check that power supply is correct.
check for loose cable
connections and hot cables
check that motor cooling intake is
not blocked or obstructed.
to resart the compressor:
allow to cool for a few minutes and
press the on/off switch.
fig.14
ssc11003 Issue: 1 - 03/05/13