Download Print this page
Sealey SAC0502B Instructions Manual

Sealey SAC0502B Instructions Manual

Compressors 50ltr/2.0hp, 100ltr/2.0hp, 150ltr/2.0hp direct drive

Advertisement

Quick Links

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the operator to
read, understand and comply with the following: You must check all
electrical products, before use, to ensure that they are safe. You must
inspect power cables, plugs, sockets and any other connectors for wear
or damage. You must ensure that the risk of electric shock is minimised
by the installation of appropriate safety devices. A residual current
circuit Breaker (rccB) should be incorporated in the main distribution
board. We also recommend that a residual current device (rcd) is
used. It is particularly important to use an rcd with portable products
that are plugged into a supply which is not protected by an rccB. If in
any doubt consult a qualified electrician. You may obtain a residual
current device by contacting your sealey dealer. You must also read
and understand the following instructions concerning electrical safety.
1.1.1. the Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are tested
by a qualified electrician, using a Portable Appliance tester
(PAt), at least once a year.
1.1.2. the Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of those
appliances and the safety of the appliance operators. If in any
doubt about electrical safety, contact a qualified electrician.
1.1.3. ensure that the insulation on all cables and on the appliance is
safe before connecting it to the power supply. see 1.1.1. and
1.1.2. and use a Portable Appliance tester.
1.1.4. ensure that cables are always protected against short circuit
and overload.
1.1.5. regularly inspect power supply cables and plugs for wear or
damage and check all connections to ensure that none is loose.
1.1.6. Important: ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is fitted
with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician. When a Bs 1363/A uK 3 pin plug is
damaged, cut the cable just above the plug and dispose of the
plug safely.
fit a new plug according to the following instructions (uK only).
a) Connect the GREEN/YELLOW earth wire to the earth
terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that
InstructIons for:
50LTR/2.0HP, 100LTR/2.0HP, 150LTR/2.0HP
DIRECT DRIVE
SAC0502B, SAC0102B, SAC0152B
Model no's:
SAC0102B illustrated.
(others will differ slightly)
1. direct compressed
air outlet.
2. tank
3. Pressure reducer.
4. Belt guard.
5. compressor unit.
6. electric motor.
7. Pressure switch.
8. Pressure gauge.
9. Pivot wheel.
10. condensate drain.
11. Wheel.
12. check valve.
all wires have been
correctly connected,
that the cable outer
insulation extends
beyond the cable
restraint and that the
restraint is tight.
double insulated
products, which are
always marked with
this symbol
fitted with live (brown)
and neutral (blue) wires
only. to rewire, connect
the wires as indicated in
diagram. DO NOT connect either wire to the earth terminal.
1.1.10. Products which require more than 13 amps are supplied
without a plug. In this case you must contact a qualified
electrician to ensure that a suitably rated supply is available.
We recommend that you discuss the installation of an industrial
round pin plug and socket with your electrician.
IMPORTANT! the use of extension leads to connect these
compressors to the mains is not recommended as the resulting
voltage drop reduces motor, and therefore pump performance.
1.2.
GENERAL SAFETY
familiarise yourself with the application and limitations of the
3
compressor.
ensure the compressor is in good order and condition before
3
use. If in any doubt do not use the unit and contact an
electrician/service agent.
WARNING! Compressor must only be serviced by an
authorised agent. DO NOT tamper with, or attempt to adjust,
pressure switch or safety valve.
Before moving, or maintaining the compressor ensure it is
3
unplugged from the mains supply and that the air tank pressure
has been vented.
Maintain the compressor in good condition and replace any
3
damaged or worn parts. use genuine parts only. Unauthorised
parts may be dangerous and will invalidate your warranty.
Original Language Version
COMPRESSORS
Yellow & Green
Earth Wire
Blue
Neutral
Wire
, are
RECOMMENDED
FUSE RATING 13 AMP
sAc0502B, sAc0102B, sAc0152B
Brown
Live
Wire
Cable
Restraint
Issue: 2 - 24/10/11

Advertisement

loading

Summary of Contents for Sealey SAC0502B

  • Page 1 SAC0502B, SAC0102B, SAC0152B Model no's: thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Introduction And Specifications

    Heavy-duty drive guards protect belt and flywheel that is designed to force air over the pump to aid cooling. 2.1. SPECIFICATIONS Model: ............SAC0502B ......SAC0102B ......SAC0152B Motor output (HP): ..........2 .........2 ..........2 Voltage / Phase: ..........230/1 ........230/1 ........230/1 Input current: ............13A ........13A ........13A speed (rpm): .............1400 ........1400 ........1400...
  • Page 3: Operation

    4.7. on Models sAc0502B and sAc0102B, the output pressure is ranging from -5°c to 45°c (viscosity 5W50). We do not regulated by the pressure regulator (fig.6.2). turn the knob recommend using mineral oil in these compressors.
  • Page 4: Troubleshooting

    WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, www.sealey.co.uk...

This manual is also suitable for:

Sac0102bSac0152b