5.6
scheduled maintenance table
maintenance
daily
operations
drain condensation
Check oil level
Clean intake filter
Check for oil leaks
Check cut-out
Replace oil
General cleaning of
compressor
Internal & external
inspection of tank
Replace air filter
Check tube fittings
and electrical
connections
6.
TROUBlE SHOOTING
FaULt
Pressure drop in the tank.
Pressure switch valve leaks when compressor
is idle.
Compressor stops and does not restart.
Compressor does not stop at max. pressure.
Compressor does not stop at max. pressure.
Compressor noisy with metallic knock.

declaration of conformity

direct drive compressor
model: sa2250/2.v2
2006/42/EC machinery directive
87/404/EEC Pressure Vessel directive
2006/95/EC low Voltage directive
2004/108/EC EmC directive
93/68/EEC CE marking directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts
without prior notice. importaNt: No liability is accepted for incorrect use of this equipment. WarraNtY: Guarantee is 12 months from
purchase date, proof of which will be required for any claim. iNFormatioN: For a copy of our latest catalogue and promotions call us on
01284 757525 and leave your full name and address, including postcode.
100 hrs
200 hrs
500 hrs
Air leaks at connections.
Non-return valve seal defective.
Pressure switch fault.
Head gasket or valve fault.
Bearing or piston damage.
We, the sole importer into the UK, declare that the product listed here is in conformity with the following standards and directives.
The construction file for this product is held by the manufacturer and may be inspected, by a national authority, upon
Signed by mark Sweetman
sole UK distributor
sealey Group,
Bury St. Edmunds, Suffolk.
caUse
motor failure.
Filter clogged.
request to Jack Sealey ltd.
01284 757500
01284 703534
remedY
Run compressor to max. pressure, switch off.
Brush soap solution over connections and look
for bubbles. Tighten connections showing leaks.
If problem persists contact Authorised Service
Agent.
Empty the air tank, remove the non-return
valve cap '3' (fig 6) and clean, or if necessary
replace, the seal '1 '.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
Replace filter element.
Contact Authorised Service Agent.
Contact Authorised Service Agent.
For Jack Sealey Ltd.
28th February 2008
Sole importer into the UK
of Sealey Power Products
www.sealey.co.uk
W e b
sales@sealey.co.uk
email
fig 6
SA2250/2.V2 - 2 - 280208

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SA2250/2.V2 and is the answer not in the manual?

Table of Contents