7-30
Electrical Installation

X14, Mains Voltage Synchronization

Description
Graphic Representation
Connection cross section
Connection
Pin no.
Description
3
mains connection phase L3 before choke
2
mains connection phase L2 before choke
1
mains connection phase L1 before choke
The X14 interface is only available for regenerative supply units
(HMV01.1R). It is used to connect the mains voltage synchronization.
Fig. 7-36:
X14
Design
Type
LE 7,62 M PC 4,0 / 3G
Fig. 7-37:
Design
Cross section
single-wire
[mm²]
1,5 - 4
Fig. 7-38:
Connection cross section
Fig. 7-39: Connection X14
3
2
1
hmv_X14
Number of poles
3
Cross section
multiwire
[mm²]
1,5 - 4
Level
max. 900V
max. 900V
max. 900V
DOK-INDRV*-HMV-*******-PR01-EN-P
Rexroth IndraDrive
Type of design
Connector on device
Cross section
in AWG
Gauge No.
16 - 12
Notes
current load max. 5A
current load max. 5A
current load max. 5A