Hmv01.1R-W0018, -W0045, -W0065 - Bosch Rexroth IndraDrive HMV01.1E-W0030 Project Planning Manual

Supply units
Hide thumbs Also See for Rexroth IndraDrive HMV01.1E-W0030:
Table of Contents

Advertisement

7-8
Electrical Installation

HMV01.1R-W0018, -W0045, -W0065

Designation
kind of connection (mode of operation at
the mains)
mains input voltage (rated voltage)
transient overvoltage limit values
mains frequency
Maximum mains frequency change per
time unit
mains input continuous current (r.m.s.
value)
connected mains power with DC bus
choke (at max. DC bus power)
power factor (cosϕ)
DC bus voltage (range)
upper DC bus voltage limit (shutdown
threshold)
lower DC bus voltage limit (shutdown
threshold)
continuous DC bus power (at U
continuous DC bus power depending on
mains input voltage
DC bus peak power
(for max. 0,3 s with a preload of
0,6 x I
and 40 °C ambient
LN cont
temperature)
braking resistor switch-on threshold
continuous brake power (braking resistor)
maximum brake power (braking resistor)
brake energy absorption (braking resistor)
DC bus capacity
output voltage
overload capacity
factor / duration
power dissipation
Symbol
-
U
LN
U
L trans max
f
LN
df
/t
LN
I
L cont
S
LN (L_DC)
cosϕ
U
DC
U
DC limit (max)
U
DC limit (min)
=400V)
P
LN
DC cont
P
DC peak
U
DC (R_DC On)
C
DC
U
out
eff
I
out_max1/
I
out_cont1
P
Diss
Fig. 7-4:
Technical data
Unit
HMV01.1R-
W0018
-
V
380 -10% to 480 +10%
V
Hz
Hz/s
A
30
kW
18
-
V
750 (controlled)
V
0,75 * ¥2 * U
V
kW
18
at U
< 400 V: 1% power reduction per 4 V
LN
at U
> 400 V: no power increasing
LN
kW
45
V
kW
0,4
kW
36
kWs
80
µF
705
V
750 (controlled)
A
(related to rated power)
W
290
Rexroth IndraDrive
HMV01.1R-
HMV01.1R-
W0045
W0065
3-phase
1200
48 to 62
2% * f
LN
70
100
45
65
1
900
LN
45
65
112
162
820
0,4
0,4
90
130
100
150
1880
2820
factor 2,5
680
800
DOK-INDRV*-HMV-*******-PR01-EN-P