ZENER VARIDRIVE SOLUTIONS
Multiple Display Readout:
Press
'ENTER' to step through the various displays.
DC Voltage from Array
550V
675W/m^2
0.9kW
SOLAR
1425kwhrs
190hours
30.0Hz
30.0
EN
30.0Hz
7.2kW
80.0%
14.1A
Pv
4.7 Bar
Sv
4.7
EN REM
30.0Hz
80%
14.1A
1100rpm
IM00130
Feedback from Irradiance sensor
On each display, this line flashes between
O
operating status and other messages. See
N
message description below
Display of Actual speed (TOP)
and set speed (BOTTOM)
REM
When PID is used, this displays
the Process Variable (PV) and
the Setpoint Variable (SV) in
the customised units
P a g e
| 22
ZENER ECODRIVE® 8000
EN
LOC
REM
SOLAR ON
Lo solar
TRACKING
AC Pwr
SFC
C LIMIT
I2t
OC
<DRY>
<FULL>
Lo Pressure
Hi Pressure
NO SIGNAL
Under Min Hz Operating Under minimum speed
PV Only
AC + PV
See the ZENER 8000 manual for other standard and
customised trip messages & warnings.
20/07/2018 3:59 PM
Enabled.
Local Mode Active.
Remote Mode Active.
Operating in Solar Mode.
DC bus or irradiance below lower
threshold entered.
Limiting output due to reduced
solar power.
Operating on the aux AC power
source.
Solar Function Conflict. This is a
Conflict between PV DC volts &
Irradiance sensor feedback.
Current limit warning. Motor
current at the maximum current
limit setting.
Motor Overload trip.
Over Current trip.
Bore/Well is Dry. Will attempt
restart after delay.
Pump not running because tank is
Full. Level switch indicating tank
full.
Lo Pressure Trip. Pressure from
transducer reading below set point
for preset time period.
Hi Pressure Trip. Pressure from
transducer reading above set point
for preset time period.
No Signal from Transducer.
setting for set period of time.
Digital input selected for Solar only
operation
Digital input selected for Solar and
AC operation