Page 1
ZENER VARIDRIVE SOLUTIONS ZENER 8000 High Performance Output Filter IP00 Series Instruction Manual Document: IM00168 Printed: 18 March 2019...
Page 2
SAFETY Your ZENER 8000 must be applied, installed and operated in a safe manner. It is the responsibility of the user to ensure compliance with all regulations and practices covering the installation and wiring of your ZENER 8000.
High Performance Output Filter – IP00 Series Explanation of Symbols Indicates a condition or practice that, if the warning is not strictly WARNING observed, could result in personal injury or death. Indicates a condition or practice, if the caution is not strictly...
ZENER 8000 Warnings This manual should be read in conjunction with the ZENER 8000 Installation Manual (IM00124). Read all operating instructions before installing, wiring, operating, servicing or inspecting the High Performance Output Filter. Ensure that the instruction manual is made available to the final user of the product as well as all personnel involved in any aspect of installation, adjustment or maintenance.
High Performance Output Filter – IP00 Series Performance The following benefits can be realised with the High Performance Output Filter when connected between the ZENER 8000 inverter and a motor: Significant reduction of RF voltages and currents achieving 40dB to 45dB attenuation.
ZENER 8000 Mechanical Installation Information Dimensions Model Dimensions (A x B X C) Weight Mounting holes AHP0070 200 x 280 x 150 10 kg AHP2200 AHP3150 14mm Diameter 650 x 335 x 410 600mm x 250mm centres AHP3900 AHP4900 130 kg...
Do not allow metal shavings or any other conductive material to enter the enclosure or damage may result. Operating Considerations Zener recommends that the associated ZENER 8000 inverter be set for an audible switching frequency of 2kHz. Confined spaces are generally defined in Workplace Health and Safety (WH&S) regulations to mean spaces where special precautions are necessary to ensure a safe breathing atmosphere, or there is limited access for escape/rescue in case of emergency.
* If the High Performance Output Filter is not mounted adjacent to the inverter on the same mounting panel, inside a metal enclosure, screened power cable may be required between the inverter and filter. If using screened cable, refer to ZENER 8000 Installation Manual for EMC Installation practices.
High Performance Output Filter – IP00 Series +B Terminal The ZENER 8000 +B/BR+ terminals are supplied as a factory fitted option. The following table lists the part numbers corresponding to ZENER 8000 inverters from 15A to 490A. Description Part Number...
242A AHP3150 315A 347A AHP3900 390A 429A AHP4900 490A 539A 630W Operation at higher Audible Frequency or at speeds >50Hz may require derating. The filter is matched to the ZENER 8000 to allow for operation at temperatures above 40°C. IM00168...