Wells MDW100 Quick Start Manual

Modular dry well

Advertisement

INSTALLATION REQUIREMENTS

Do not install closer than 4.125 inches (105 mm) to front wall,
one [1] inch (25 mm) to back and side walls, and 6.75 inches
(171 mm) to a surface below the unit. If storage is to be used
underneath, it is recommended that a baffle be placed 8.5
inches (216 mm) below the unit to avoid contact with elevated
temperatures. The unit will need to be accessible from the
bottom after installation is complete.
A proper electrical connection based on the units electrical
specifications will be necessary for installation. This must
be wired and connected by a licensed electrician. Electrical
installation will need to pass local electrical codes.

FABRICATION

i. Lay out cutout dimensions on countertop and front apron.
ii. Lay out control panel mounting holes in counter apron using
the provided dimensions. The mounting holes should be
0.144 inch (3.7 mm) in diameter [drill size 27].
iii. Cut out the holes. On many countertops, reinforcement may
be needed to stiffen the countertop.

INSTALLATION INSTRUCTIONS

Do not disconnect the control box from the modular unit.
i. Remove the knobs and faceplate from the control box. Pass the
control box through the countertop cutout, and then through
the apron cutout. This will require the box to be rotated so the
mounting tabs clear the hole. Next, lower and position the
modular section into countertop cutout.
ii. Before final seating of modular section to countertop, apply
a bead of silicone sealant to the underside of the grey gasket
material supplied on the mounting flange. From underneath,
insert screwdriver into the slots in the Wellslok frame and twist
clockwise to move the ears outward as required to secure the
flange tightly to countertop.1
iii. Mount the control box to apron cutout using #10 sheet metal [or
wood] screws to the facing side where the holes were drilled.
iv. Run wiring through the conduit knockout to the terminal block,
making connection as shown in the unit's wiring diagram to the
correct power source.
v. Mount the front panel onto the control box using the provided
hardware and place the knob on. At this point, you should be
able to power on the unit and check for proper operation.
WELLS BLOOMFIELD, LLC
265 Hobson St
Telephone 888 356 5362
www.wellsbloom ield.com
Smithville, Tennessee 37166
Fax 314 781 5445
MDW100 Modular Dry Well
2.25 in. (57 mm)
minimum clearance
on non-control side
4.125 in. (105 mm)
minimum clearance
on control side
3.125 in.
(79 mm)
5 in.
(127 mm)
4.875 in.
(124 mm)
7/8 in.
(22 mm)
1/4 in.
(6 mm)
The unit's overall depth is 12.125 inches (308 mm) will sit
approximately 11.75 inches (298 mm) below the counter
surface depending on counter thickness.
When installing multiple units, each unit will need a space
of at least 2.125 inches (54 mm) between the cutouts on
the long dimension sides [A] and at least 3.625 inches
(92 mm) between cutouts on the short dimension side [B].
MODEL
TOTAL kW
0.61
MDW100
0.8
The supply wire will need to be the correct gauge as described by
the National Electrical Code and be rated to at least 167°F (75°C).
1 Wellslok adapter kit will use hex screws to tighten and allow
installation on countertops up to 1.5 inches (38 mm) thick.
Installation Instructions
13.5 in.
(343 mm)
[B]
22.5 in.
dry well cutout
(572 mm)
countertop
[A]
control cutout
see detail A
3 in.
(76 mm)
0.144 inch ø
(3.7 mm ø)
[#27 drill]
VOLTS, PHASE
AMPS
208, 1Φ
2.9
240, 1Φ
3.3
Printed in the U.S.A. • 2M-Z20755 • Rev B •
The owner is responsible for proper installation as
described above. Please refer to the owner's manual
for information regarding installation or use.
05.2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MDW100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wells MDW100

  • Page 1 MDW100 Modular Dry Well Installation Instructions 2.25 in. (57 mm) minimum clearance on non-control side INSTALLATION REQUIREMENTS 13.5 in. (343 mm) Do not install closer than 4.125 inches (105 mm) to front wall, one [1] inch (25 mm) to back and side walls, and 6.75 inches (171 mm) to a surface below the unit.
  • Page 2 22593 22592 Printed in the U.S.A. • 2M-Z20755 • Rev B • 05.2018 WELLS BLOOMFIELD, LLC www.wellsbloom ield.com • The owner is responsible for proper installation as 265 Hobson St Smithville, Tennessee 37166 •...

Table of Contents