U-Line 1000 Series Quick Start Manual

U-Line 1000 Series Quick Start Manual

Hide thumbs Also See for 1000 Series:

Advertisement

QUICK START GUIDE
1000 Series • CLR1215 • 115 V / 60 Hz

Advertisement

Table of Contents
loading

Summary of Contents for U-Line 1000 Series

  • Page 1 QUICK START GUIDE 1000 Series • CLR1215 • 115 V / 60 Hz...
  • Page 2 U-Line Customer Care must be contacted immediately at +1.800.779.2547. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 3: Table Of Contents

    11. Control Operation 11. First Use 11. Ice 13. Warranty 1 year + 1 with registration This product is eligible for an additional one-year warranty at no charge when you register your product on u-line.com. See complete warranty for details.
  • Page 4: Safety And Warning

    QUICK START GUIDE QUICK START GUIDE u-line.com u-line.com Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5: Environmental Requirements

    QUICK START GUIDE QUICK START GUIDE u-line.com u-line.com Environmental Requirements OUTDOOR UNITS This unit is designed to operate between 50°F (10°C) and 115 V UNITS 100°F (38°C). Higher ambient temperatures may reduce This model is intended for indoor/interior applications only the unit’s ability to reach low temperatures and/or reduce...
  • Page 6: Electrical

    Water Hookup PREPARE PLUMBING WARNING The water valve uses a standard 1/4" (6.35 mm) compression fitting. U-Line recommends using accessory SHOCK HAZARD — Electrical Grounding water hookup kit - part # WATERHOOKUP. The kit Required. Never attempt to repair or perform includes a 10’...
  • Page 7 QUICK START GUIDE QUICK START GUIDE u-line.com u-line.com 4. On the back panel, CAUTION break away filler feature in bushing with flat Do not use any plastic water supply line. The line screwdriver. is under pressure at all times. Plastic may crack...
  • Page 8: Drain

    DRAIN CONNECTION CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity A gravity drain may be used if: style drain connection. For assistance in Drain line has at least a 1"...
  • Page 9: Door Swing

    (Optional Hook-Up) spigot assembly, or does not otherwise meet the requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see Valve DRAIN PUMP section in the User Manual.
  • Page 10: Door Adjustments

    These general instructions apply to all models. For further details, see user guide for your specific model at u-line.com. Align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool properly, or excessive frost may form in the interior.
  • Page 11 QUICK START GUIDE QUICK START GUIDE u-line.com u-line.com 3. Remove door by tilting forward and lifting door off 2. Remove magnet assembly from door with T-10 TORX bottom hinge. Retain shoulder washers; they will driver. Be sure to only remove the two screws holding be reused.
  • Page 12: General Installation

    QUICK START GUIDE QUICK START GUIDE u-line.com u-line.com General Installation INSTALLATION 1. Plug in the power/electrical cord. LEVELING INFORMATION 2. Gently push the unit into position. Be careful not to 1. Use a level to entangle the cord or water and drain lines.
  • Page 13 A adjust panel as necessary. Tighten screws upon robust tape may also completion. be used. U-Line recommends the use of bar clamps to 15.Starting at the corners, re-install the gasket into the Door/Drawer secure the panel to gasket channel in the frame.
  • Page 14: Control Operation

    This unit is Star-K certified. See www.star-k.org for more details. First Use All U-Line controls are preset at the factory. Initial startup ICE CUBE THICKNESS ADJUSTMENT requires no adjustments. NOTICE Ice thickness adjustment should only be made NOTICE one increment at a time.
  • Page 15 Ice cubes in any given batch will vary, so it is necessary to choose cubes from the sample area for comparison when making adjustments. Copyright © 2014/2017 U-Line Corporation. All Rights Reserved. Publication Number 30629 11/2019 Rev.A...
  • Page 16: Warranty

    For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.

Table of Contents